13.07.2015 Views

SITC OF LT Switch gear for Doordarshan, HPT Vizag - All India Radio

SITC OF LT Switch gear for Doordarshan, HPT Vizag - All India Radio

SITC OF LT Switch gear for Doordarshan, HPT Vizag - All India Radio

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

equipment and materials, clearances and spaces requiredbetween various portions of equipment and any otherin<strong>for</strong>mation specifically requested. Bolted joints shall be asper DIN standard bolting schedule. Visual indicator shall beprovided to inspect tightness of all bus bar/dropper boltedjoints. <strong>All</strong> drawout tap-offs on Main <strong>LT</strong> Panel droppers shallbe properly designed silver plated contacts. A contact platearrangement <strong>for</strong> dropper tap-off to avoid wear & tear offdroppers is essential.2.13.2 Appropriate coloured bands shall be provided on main busbars and vertical bus bars <strong>for</strong> providing phase identificationin line with requirement of IS-375.2.13.3 Provision shall exist in a separate chamber <strong>for</strong> mountingadequate insulated auxiliary bus bars,, supported onmoulded supports <strong>for</strong> control/interlocking/ annunciationpurposes as required. The wiring shall be directly tappedfrom auxiliary bus bars to the withdrawable units. Unit tounit looping shall not be permitted. The material of controlpower supply buses shall be electrolytic copper. Thematerial <strong>for</strong> space heater power supply buses shall be sameas that <strong>for</strong> the main power buses.2.13.4 The clearance and creepage distances shall not be lowerthan the values specified below :a) Minimum clearance between two live conductors –20 mmb) Minimum clearance between live part & accidentallydangerous part– 20mmc) Minimum creepage distance – 28 mm2.13.5 Unless specified otherwise in particular project, temperaturerise bus bars when carrying rated current shall be limited to35 deg C above ambient temperature of 50 deg C.2.13.6 Location of bus bars shall be at the top <strong>for</strong> panels withbottom cable entry and at the bottom <strong>for</strong> panels with topcable entry.2.13.7 Bus bar material shall be either copper or aluminum as perspecifications.2.13.8 Room dimensions are provided in the drawing <strong>for</strong> reference.2.14 TOOLS AND APPLIANCES Compliance2.14.1 The vendor shall supply without any extra cost one set ofspecial tools and appliances that may be required <strong>for</strong>carrying out the maintenance, special inspection, etc., of theequipment offered.2.14.2 Vendor shall also furnish list tools and appliances required<strong>for</strong> different equipment.2.15 GUARANTEE:Equipment shall be guaranteed <strong>for</strong> a period of 12 monthsfrom the date of commissioning.14

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!