13.07.2015 Views

Processing Control Center Area - Environmental Program at KSC

Processing Control Center Area - Environmental Program at KSC

Processing Control Center Area - Environmental Program at KSC

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

LUCIP-SWMU 101<strong>KSC</strong>-TA-11462SITE LOCATIONThe PCCA is loc<strong>at</strong>ed in the Vehicle AssemblyBuilding (VAB) <strong>Area</strong> of <strong>KSC</strong>, southwest ofthe Crawlerway on the intersection of UtilityRoad and VAB Road. The facility is borderedby the Orbiter <strong>Processing</strong> Facility (K6-0894)to the north, Utility Road to the east, VABRoad to the south, and railroad tracks to thewest (Figure 1). The groundw<strong>at</strong>er use controlarea covered by the LUCIP is shown onFigure 2. Coordin<strong>at</strong>es of the corners of theLUC are provided on Figure 2 in the US St<strong>at</strong>ePlane Coordin<strong>at</strong>e System NAD 1983, meters,Florida East.SITE CONTAMINATION ANDCONTROLThe concentr<strong>at</strong>ion of vinyl chloride present ingroundw<strong>at</strong>er is above the FDEP’sGroundw<strong>at</strong>er Cleanup Target Level (GCTL)but is less than the FDEP N<strong>at</strong>ural Attenu<strong>at</strong>ionDefault Concentr<strong>at</strong>ion. Since groundw<strong>at</strong>erexceeds the FDEP GCTL, LUCs prohibitingthe use of groundw<strong>at</strong>er are required until thecleanup level is achieved. The current andprojected land use of the PCCA does notinclude the use of site groundw<strong>at</strong>er; therefore,there is no current or projected exposure risk.DECISION DOCUMENTA St<strong>at</strong>ement of Basis (SB) establishesinstitutional controls as a component of theremedy for the site. The SB for the site, <strong>KSC</strong>document number <strong>KSC</strong>-TA-11461, isavailable for review by contacting the <strong>KSC</strong><strong>Environmental</strong> Assurance Branch <strong>at</strong> telephonenumber (321) 867-8402.IMPLEMENTATIONInstitutional controls will be implemented bythe <strong>KSC</strong> <strong>Environmental</strong> Assurance Branch inaccordance with their RCRA permit and aLand Use <strong>Control</strong> Assurance Plan included inthe Memorandum of Agreement (MOA) 2between NASA and the FDEP, effectiveFebruary 23, 2001. Upon approval of thisLUCIP, it will be incorpor<strong>at</strong>ed into the permitby reference. Property transfer (if conductedin the future) will be conducted in accordancewith Section X of the MOA.<strong>KSC</strong>’s <strong>Environmental</strong> Assurance Branch willprovide <strong>KSC</strong>’s Master Planning Office withsurvey coordin<strong>at</strong>es of the LUCs. Restrictionswill specify limit<strong>at</strong>ions on development andreuse for the area for as long as LUCs arenecessary to protect human health and theenvironment.MONITORINGQuarterly inspections to monitor th<strong>at</strong> theinstitutional controls specified herein are inplace and oper<strong>at</strong>ing will be conducted by<strong>KSC</strong>’s <strong>Environmental</strong> Assurance Branch. Theinspections will verify th<strong>at</strong> no groundw<strong>at</strong>eruse is occurring <strong>at</strong> the site.2 By separ<strong>at</strong>e MOA effective February 23, 2001, with the FDEP and <strong>KSC</strong>, on behalf of NASA, agreed to implement <strong>Center</strong>-wide, certainperiodic site inspections, condition certific<strong>at</strong>ion, and agency notific<strong>at</strong>ion procedures designed to ensure the maintenance by <strong>Center</strong>personnel of any site-specific LUCs deemed necessary for future protection of human health and the environment. A fundamental premiseunderlying execution of th<strong>at</strong> agreement was th<strong>at</strong> through the <strong>Center</strong>'s substantial good faith compliance with the procedures called forherein, reasonable assurances would be provided to the FDEP as to the permanency of those remedies which included the use of specificLUCs.Although the terms and conditions of the MOA are not specifically incorpor<strong>at</strong>ed or made enforceable herein by reference, it is understoodand agreed by NASA <strong>KSC</strong> and FDEP th<strong>at</strong> the contempl<strong>at</strong>ed permanence of the remedy reflected herein shall be dependent upon the <strong>Center</strong>'ssubstantial good faith compliance with the specific LUC maintenance commitments reflected herein. Should such compliance not occur orshould the MOA be termin<strong>at</strong>ed, it is understood th<strong>at</strong> the protectiveness of the remedy concurred in may be reconsidered and th<strong>at</strong> additionalmeasures may need to be taken to adequ<strong>at</strong>ely ensure necessary future protection of human health and the environment.PCCA LUCIP Rev. 0 2 3/31/11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!