6. Test ResultThe test result includes alarm test result, error code test result, pointer test result, overheadtest result, TCM test result, transparency test result, frequency test result and tributary test result,with the interface as in Figure 6-1. All test result menus have a save function. Click on the“Save“ shortcut key to save up the current test results.6.1. Alarm Test ResultFigure 6-1 test resultFor alarm test result interface, see Figure 6-2 as follows:Figure 6-2 Alarm Test Result“Alarm type”:34
PDH part: including continual seconds of LOS, AIS, LTI, LOF, RAI, CRCL, MAIS, CASL, MRAI,Pat AIS and Pat LSS. (Only in E1 mode)<strong>SDH</strong> part: including LOS, LOF, RS TIM, MS AIS, MS RDI, AU AIS, AU LOP, HP UNEQ, HP RDI,HP TIM, HP PLM, LTI, Pat AIS, Pat LSS, TU AIS (grey when set up as C4), TU LOP (grey when setup as C4), LP UNEQ (grey when set up as C4), LP RDI (grey when set up as C4), RFI (grey whenset up as C3 or C4), LP TIM (grey when set up as C4) and LP PLM (grey when set up as C4).In any interface, click on the “Start” shortcut key to start synchronous counting and operation.Click on ”Stop” button to stop. Click on the “Chart” shortcut key to generate a dynamic histogram ofalarm test results in this interface directly.6.2. Error Code Test ResultFor error code test result interface, see Figure 6-3 as follows:Figure 6-3 Error Code Test Result“Error type”:PDH part: including error code counting, sec & rate of ECOD, EFAS, ECRC, REBE and EBIT.(Only in E1 mode)<strong>SDH</strong> part: including error code counting, sec & rate of B1, B2, MRAI, HP B3, LP B3 (grey whenset up as C12 or C4), HP REI, LP REI (grey when set up as C4), EBIT and BIP2 (grey when set upas C3 or C4).In any interface, click on the “Start” shortcut key to start synchronous counting and operation.Click on the exit button to stop. Click on the “Chart” shortcut key to generate a dynamic histogram oferror test results in this interface directly.6.3. Pointer Test ResultFor pointer test result interface, see Figure 6-4 as follows:35