13.07.2015 Views

Conventional Smoke Detector Bases P.1.20.01-3 - ORR Protection

Conventional Smoke Detector Bases P.1.20.01-3 - ORR Protection

Conventional Smoke Detector Bases P.1.20.01-3 - ORR Protection

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CONVENTIONAL SMOKE DETECTOR BASESDESCRIPTION4” and 6” Series <strong>Smoke</strong> <strong>Detector</strong> BaseThe 4" and 6" Series <strong>Smoke</strong> <strong>Detector</strong> <strong>Bases</strong> are designed specifically for use with the 67-1033 Ionization <strong>Smoke</strong> <strong>Detector</strong>,63-1024 Photoelectric <strong>Smoke</strong> <strong>Detector</strong>, 63-1025 Photoelectric with Heat <strong>Smoke</strong> <strong>Detector</strong>, and the 60-1029 or 60-1030Fixed Temperature/Rate-of-Rise Heat <strong>Detector</strong>. The 6" base is an electronics free base featuring a plastic tamper-locklug. Each base is equipped with a resistor. Refer to the chart (below) for additional specifications. The 4" base is a 4"version of the 6" base.Compatible <strong>Bases</strong> 6”67-1034 (430 Ω) NS6-22467-1035 (220 Ω) NS6-220Compatible <strong>Bases</strong> 4”67-1036 (430 Ω) NS4-22467-1037 (220 Ω) NS4-220Two Wire Auxilliary Relay <strong>Bases</strong>Alarm Current 43mA (58mA @ 30.0V Max)Model 63-1012 is designed specifically for use with the 67-1033 Ionization <strong>Smoke</strong> <strong>Detector</strong>, 63-1024 Photoelectric <strong>Smoke</strong><strong>Detector</strong>,63-1025 Photoelectric with Heat <strong>Smoke</strong> <strong>Detector</strong>, or the 60-1029 or 60-1030 Fixed Temperature/Rate-of-RiseHeat <strong>Detector</strong>. The 63-1012 is a 6" base with two sets of Form "C" relay contacts (DPDT, 1 amp at 30 VDC and 0.5amp at 125 VAC) when this type of function is needed. It is Underwriters Laboratories approved for releasing deviceservice.The 63-1012 is also approved for use with Fike <strong>Conventional</strong> Models 67-1016, 63-1007, 63-1016, 60-1020 and 60-1022.APPROVALS• UL Listed - S4021• FM Approval - 3010873Resistor shown is forexample only. Not allannunciators have in lineresistance.Note: Wiring Terminals for the NS4 and NSG are identical.Annunciation device must be current limited to 20 mA @ 24 VDC maximum. Not currentlimiting current could result in damage to the detector or cause a no alarm conditionResistor shown is forexample only. Not allannunciators have in lineresistance.Note: Wiring Terminals for the NS4 and NSG are identical.Form No. <strong>P.1.20.01</strong>-3704 S. 10th Street · P.O. Box 610 · Blue Springs, Missouri 64013-0610 U.S.A. · (816) 229-3405 · (816) 229-4615 · www.fike.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!