INTRODUCTION 2SENSOR TECHNOLOGY 2APPLICATION 3POSITIONING 6LIMITATIONS 8HOW TO INSTALL YOUR SMOKEALARM 101 Preparation2 Install mounting plate3 Install 9V battery4 Fit your smoke alarm5 Test your smoke alarmOPERATION 14Normal ConditionLow Battery ConditionBATTERY REPLACEMENT 14OPERATIONALARM TEST 16ALARM SMART SILENCE 18ROUTINE MAINTENANCE 20WHAT TO DO IN CASE OF FIRE INYOUR HOME 21REPAIR 22TROUBLESHOOTING 23DISPOSAL 26HOW TO MAKE YOUR HOME SAFER 27WARRANTY 29RETURNS 30PRODUCT RANGE 31


2INTRODUCTIONThis user manual covers the following twoproducts, <strong>FireAngel</strong> SI-601 (Ionisation) <strong>Smoke</strong><strong>Alarm</strong> and SO-601 Toast Proof (Optical) <strong>Smoke</strong><strong>Alarm</strong>.Congratulations! You’ve made a wise investmentin an innovative product and your personalsafety. The <strong>FireAngel</strong> smoke alarms covered bythis manual form part of a new generation ofdomestic life safety products from <strong>FireAngel</strong>Limited. The <strong>FireAngel</strong> range of products isconstantly being improved and expanded. Pleasevisit www.fireangel.co.uk to find out about thelatest additions to our product range.IMPORTANT: This user manualcontains important informationregarding the operation of your <strong>FireAngel</strong>smoke alarm. Ensure you read this user manualfully before installing and operating the alarm.If you are installing this smoke alarm for use byothers, you must leave this manual (or a copyof it) with the end user.SENSOR TECHNOLOGYThere are two main types of smoke alarm. TheSI-601 Standard <strong>Smoke</strong> <strong>Alarm</strong> uses an ionisationtype sensor to detect the presence of smoke.Ionisation type smoke alarms are generally moreeffective at detecting fast, flaming fires whichconsume combustible materials rapidly and spreadfire quickly. The SO-601 Toast Proof <strong>Smoke</strong> <strong>Alarm</strong>uses an optical (photoelectric) type sensor whichis more effective at detecting slow burning fires,which can smoulder for hours before bursting intoflames.TOAST PROOF = less sensitive to cookingfumes. (Optical alarms are less prone tonuisance alarms due to cooking fumes.)For maximum protection, use both types ofsmoke alarms on each level of your home


APPLICATIONWARNING: Your <strong>FireAngel</strong> smokealarm can be installed into a newbuild property as additional protection toan existing smoke detection system only. Itcannot be used as a substitute for a hard wiredsystem as required in new build properties. Inthis type of property the building regulationsrequire alarms to be interlinked. You canobtain further information from your local fireservice or building control department at yourlocal council offices. These sources generallyprovide advice on new builds or projects thatrequire planning permission.where the temperature is normally between 4°C(40°F) and 38°C (100°F). The type of smoke alarmused in each location should be appropriate to theenvironment. Check the section on ‘Positioning’ toensure that the smoke alarm is to be correctlypositioned for the particular dwelling into which itis intended to be installed.WARNING: The alarm positionsshown overleaf are based on typicalhomes. Construction and layout of individualdwellings will vary, so this should be regardedonly as a guide. Check with your local firestation for further guidance.Your smoke alarm typically meets the minimumrequirements for family living units in existingbuildings, as long as at least one unit is installed oneach floor/level of your property.In order to achieve the earliest fire warning, werecommend that a smoke alarm is fitted in all rooms3


EXISTING HOMESMINIMUM RECOMMENDATIONSBEDROOMHALLBEDROOMRECOMMENDED FOR ADDITIONAL PROTECTIONDINING ROOMLOUNGENOTE: Kitchens should be covered by aself contained heat detector.CELLAR4


Multi-family or mixed occupant residence(Tenancy building, student accommodation)Your <strong>FireAngel</strong> smoke alarm can also be used inindividual flats and bedsits, providing the sameconditions are met as for a single-family residence.However, there must already be a primaryfire detection system that meets regulatoryrequirements for common areas such as lobbiesand hallways.Institutions and HotelsThis includes motels, hospitals, day care facilities,long-term health care facilities, boarding housesand dormitories. Your smoke alarm can be usedin individual sleeping/resident rooms, providingthe same conditions are met as for a singlefamilyresidence. However, there must alreadybe a primary fire detection system that meetsregulatory requirements for common areas suchas lobbies and hallways. Use of this smoke alarmin common areas may not provide sufficientfire warning to residents or meet regulatoryrequirements.This smoke alarm is designed to operate asstandalone smoke alarm.WARNING: This <strong>FireAngel</strong> smokealarm will not communicate with othersmoke alarms or fire alarm systems. It is notintended as a substitute for a complete alarmsystem.Mobile Homes and CaravansThis smoke alarm is suitable for use in mobilehomes and caravans.Commercial and Industrial PremisesThis smoke alarm is not intended for any nonresidential,commercial or industrial application,nor for any other purpose than described above.5


POSITIONINGIonisation type smoke alarms are generallymore effective at detecting fast, flaming fires whichconsume combustable materials rapidly andspread fire quickly.Examples fast flaming fires = Ignited paper, flamingcurtains and oil firesOptical (Toast Proof) smoke alarms areless prone to false alarms from cooking fumes,are therefore suitable for locations near kitchens.However optical smoke alarms are moresusceptible to nuisance alarms from steam andshould not be located too close to bathroomsand showers.Examples of slow smouldering fires = cigarette onfurniture and bedding, overheating electrical cables.It is recommended that your <strong>FireAngel</strong> smokealarm is NOT to be fitted in the followinglocations:• Bathrooms, shower-rooms, and other verydamp or humid areas, where the moisture cancause unwanted alarms.• Kitchens. Kitchens should be protected withself-contained Heat <strong>Alarm</strong>s, as the combustionparticles from cooking in kitchens willresult in unwanted alarms and permanentcontamination of the smoke alarm’s sensor.• In areas where excessive dust or dirt couldcontaminate the sensing chamber, making itover sensitive or impairing smoke entry.• In areas where the ambient temperature is notcontrolled and may regularly drift below 4°C(40°F) or above 38°C (100°F) e.g. unheatedbuildings, open attic spaces.• Very dirty, dusty or greasy areas.• In very draughty areas, such as close to ceilingfans or fresh air vents. Draughts can blowsmoke away from the alarm.• In insect infested areas. Insects can clogopenings to the sensing chamber, preventingsmoke entry or causing unwanted alarms.6


• Within 30cm (12”) of a fluorescent light fittingwhich emits electrical ‘noise’ that can preventcorrect alarm operation.• In wall positions that are more than 30cm(12”) away from the ceiling (see ‘How to installyour smoke alarm’).• In ‘dead air’ spaces (see following diagram).• Within 30cm (12”) of light fittings or otherceiling based obstructions.1 METRE(3 FEET)DEADAIR SPACESBEST LOCATION(IN CENTRE OF CEILING)100MM(4 INCHES)100MM(4 INCHES)7


WHAT ARE THELIMITATIONS OF MY SMOKEALARM?Your <strong>FireAngel</strong> smoke alarm is designed to alertyou by sounding an alarm when it senses smoke,i.e. it can only sense smoke and alert you if smokereaches it! If a fire develops in an area remote fromthe location of the smoke alarm, such as anotherroom or another level, smoke may not reach thesmoke alarm in sufficient time or quantity to senseand alert you to the danger.We recommend that as a minimum you installboth ionisation and optical smoke alarms onevery floor of your property. For comprehensivecoverage a smoke alarm should also be fitted inevery room.This smoke alarm cannot be used to provideprimary fire detection in common areas usedby different residents such as blocks of flats andhotels. The <strong>FireAngel</strong> smoke alarm may not alarmbefore a fire causes damage, injury or death, as thesmoke may not reach the smoke alarm in time.Examples include smoking in bed and violent gasexplosions. This smoke alarm may not respond ina reasonable time if it is not installed in the bestposition, or if furniture or other obstacles arelocated between the smoke alarm and the fire.WARNING: Your smoke alarm willnot operate without a battery installed.Only batteries listed on page 14 should beused and must be changed immediately whenthe low battery signal is given or the unit willfail. Test weekly, read and follow all instructionsor the unit will not operate properly.Your <strong>FireAngel</strong> smoke alarm will advise you of alow battery condition by emitting an audible ‘chirp’every 40 seconds. When this occurs you mustchange the battery in the unit within 7 days tomaintain correct operation.8


IMPORTANT: <strong>Smoke</strong> alarms are designed to alert you with an audible alarm at a levelspecified by the British Standard BS EN 14604: 2005. Closed doors, walls and high ambientnoise levels will reduce this level. Temporary or permanently impaired hearing may result in thealarm not being heard. Stereos, traffic and other loud sources may also prevent the alarm beingheard. Heavy sleepers and residents under the influence of alcohol or drugs may also not hear orrespond to the alarm. Test and check that you can hear the alarm in all circumstances. If in doubtinstall additional smoke alarms as required.WARNING: The <strong>Smoke</strong> alarm is not suitable for alerting hearing impaired residents.We recommend that specially designed warning systems be installed that will alert hearingimpaired residents.WARNING: The smoke alarm accompanying this manual employs the latest technology andis independently tested as being compliant with all the relevant British Standards. However,as with any electronic product it may fail and may not sense all types of fire within sufficient timeto alert you of the danger and provide adequate time for your escape. In order to maximise yourlevel of safety always test your smoke alarm frequently to ensure it is in full working order. Your<strong>FireAngel</strong> smoke alarm is only suitable for usein domestic/ residential applications as coveredin this manual. It is not suitable for commercialor industrial applications. It is designed tosense smoke and alert you. It will not sensecarbon monoxide, flames, heat or gas. It willnot prevent or extinguish fires.This <strong>FireAngel</strong> smoke alarm has a limited life of 10years and should not be considered as a substitutefor life or property insurance. Like all electronicequipment, it can wear out or fail. It should betested weekly and replaced immediately in theevent of failure, and replaced every 10 yearsregardless.9


HOW TO INSTALL YOURSMOKE ALARMIMPORTANT: Make sure you haveread and understood this manualbefore installing your smoke alarm.1 PreparationAttach the mounting plate to a ceiling or wall.1 PreparationIf the alarm is to be mounted on a wall, ensure themounting plate is aligned correctly. The mountingplate has an arrow moulded into the plastic. Thisindicates the orientation in which the mountingplate should be installed. This ensures that whenthe alarm is fitted the vents will be central andfacing upwards.Fixing slots10Use the fixing slots on the mounting plate as aguide when marking the position of the drill holes.With an appropriately sized drill, drill the holes andinsert the plastic fixing anchors supplied (if needed).


2 Install Mounting PlateFit the mounting plate to the ceiling or wall usingthe screws provided.2 Install Mounting Plate11


3 Install 9V BatteryIMPORTANT: Before installing yoursmoke alarm the battery must beremoved from the alarm and the protectivewrapper on the battery should be removed.The battery should then be refitted. Thebattery compartment has been designed toprevent the battery being inserted incorrectly.3 Install 9V BatteryCAUTION: The horn is designed tobe loud to wake you in an emergency.Avoid placing your ear close to the alarmwhen installing battery.Insert the battery that was provided with thealarm making sure that the positive and negativeconnections are in the correct position, seediagram. The red LED on the front should nowflash once every 40 seconds to show the alarmis active.Ensure wrapper is removedNOTE: On rare occasions the alarm may soundwhen the battery is first installed. If this happens, seeTroubleshooting on page 23.12


The backing plate has a safety mechanism whichprevents the alarm being installed without abattery. When the battery is inserted this safetymechanism is released meaning that the alarm canbe attached to the backing plate.4 Fit Your <strong>FireAngel</strong> <strong>Smoke</strong> <strong>Alarm</strong>4 Fit Your <strong>FireAngel</strong> <strong>Smoke</strong> <strong>Alarm</strong>The alarm will only lock into place in oneparticular position. Position the smoke alarmover the mounting plate lining up the central venton the front of the alarm with the ‘X’ mouldedinto the plastic on the mounting plate and turnclockwise. After one quarter turn you should feelthe alarm click into place.5 Test Your <strong>FireAngel</strong> <strong>Smoke</strong><strong>Alarm</strong>See ‘<strong>Alarm</strong> Test’ on page 1613


OPERATIONNormal conditionThe red LED on the front should flash once every40 seconds to show the alarm is active.Low Battery ConditionIMPORTANT: Your smoke alarmrequires a battery with a sufficientcapacity of power to operate correctly, thismust also be correctly installed.Should your <strong>FireAngel</strong> smoke alarm enter a lowbattery condition, the unit will emit an audible‘chirp’ once every 40 seconds. When this occursyou must replace the battery immediately. Your<strong>FireAngel</strong> smoke alarm will continue to warn of thislow battery condition for at least 7 days, however,failure to change the battery after this time wouldmean your smoke alarm has insufficient power toalert you in a real fire situation.BATTERY REPLACEMENTIMPORTANT: Only the followingbatteries can be used for replacement.Use of a battery other than thoserecommended below may have a detrimentaleffect on the detector’s operation. Use ofa lithium (long-life) battery could providepower for 10 years under normal operatingconditions, meaning there is no need for anannual battery change.Carbon-Zinc type:Eveready Energizer 1222; Gold Peak 1604S (UL).Alkaline TypeEnergizer 522; Duracell MN1604; Duracell 9VUltra; Energizer 9V Ultra+; Gold Peak 1604A.Lithium (long life) typeUltralife U9VL.14


unsure see diagram in “3. Install 9v battery”section (Page 12).a Remove the alarm from its mounting plate byturning anti-clockwisec Replace the alarm on its mounting plate, liningup the large central vent on the front of thealarm, with the ‘X’ that is moulded into theplastic on the mounting plate (if unsure seepage 13). Ensure the unit is securely fitted.b Remove the existing battery and replace witha new battery, from the list on previous page,making sure that the positive and negativeconnections are in the correct position. Ifd Test your alarm as explained in the nextsection ‘<strong>Alarm</strong> Test’.15


ALARM TESTb The unit will emit a loud (85dB at 3 meters)alarm for around 5 seconds and stopautomatically.a Press the test button in the centre andrelease.c The red LED on your alarm will flash rapidlyduring the audible signal.16


NOTE: The test button accurately tests thealarm’s smoke sensing circuit, there is no need totest your alarm with smoke. If your smoke alarmfails to give an audible test signal, please referimmediately to the troubleshooting guide at theend of this manual.WARNING: Test your smoke alarmat least once per week.17


ALARM SMART SILENCEDANGER: If your <strong>FireAngel</strong> smokealarm emits the full alarm signal andyou are not testing the unit, the smoke alarmis warning you of a potentially dangeroussituation that requires your immediateattention. Only use the alarm silence functionafter making sure that there is no ongoing fireemergency situation. Do not block the ventson the alarm or disable the smoke alarm in anyway, as this will remove your protection. In theevent of a known false alarm such as cookingfumes your smoke alarm can be silenced in thefollowing wayYour smoke alarm features “Smart Silence”technology. <strong>Smoke</strong> alarms can sometimes reactto cooking fumes or other non emergencysituations. Should your alarm sound the centraltest button can be used to temporarily silencethe alarm. Your alarm will automatically return tofull sensitivity within 10 minutes.NOTE: If the level of smoke reaching the alarm isvery high the alarm silence will be overridden andthe alarm will continue to sound.a Press and release the silence button, the alarmsound will shortly stop.18


Your alarm will silence and enter intoa reduced sensitivity reset cycle forapproximately 10 minutes.c During the reduced sensitivity reset cycle, thered LED on your alarm will flash more rapidlythan normal, approximately once every 10seconds.d Your alarm will automatically return to fullsensitivity on completion of the reset cycleand the red LED will revert to flashing onceevery 40 seconds.DANGER: Never ignore any alarm.Ignoring the alarm may result in injuryor death. If your smoke alarm activates andalarms and you are not absolutely certain ofthe source of the smoke, get everyone out ofthe house immediately.19


ROUTINE MAINTENANCEYour <strong>FireAngel</strong> smoke alarm has been designed tobe as maintenance-free as possible and althoughthe unit requires only battery maintenance for itsentire life, there are several things you must do tokeep it working properly.CAUTION: Your <strong>FireAngel</strong> smoke alarm is asealed electrical device and no attempt should bemade to open the case. Attempting to open thecase will invalidate your Warranty.TestingTest your smoke alarm once every week seesection ‘<strong>Alarm</strong> Test’ on page 16. Any test failuresshould be reported to the <strong>FireAngel</strong> TechnicalSupport Team on page 25.CleaningAs a minimum your smoke alarm should becleaned once every 3 months using your vacuumcleaner fitted with the soft brush attachment.WARNING: Your <strong>FireAngel</strong> smokealarm may false alarm when it is beingcleaned using a vacuum cleaner.IMPORTANT: Do not use solventsor cleaners on your <strong>FireAngel</strong> smokealarm, as they may cause damage to thesensor or circuitry. The unit can be wiped witha slightly damp cloth.CAUTION: Do not paint the smokealarm as this may block the openingsand prevent smoke from entering the sensor.20


WHAT TO DO IN CASE OFA FIRE IN YOUR HOME• If you have made a family escape plan andpracticed it with your family, you have increasedtheir chances of escaping safely. Go over thefollowing rules with your children each timeyou have fire drills. This will help everyoneremember them in case of a real emergency.• Don’t panic, stay calm. Your safe escape maydepend on thinking clearly and rememberingwhat you have practiced.• Notify every member in the residence of thefire.• Get out of the house as quickly as possible.Follow a planned escape route. Do not stop tocollect anything or to get dressed.• Feel the doors to see if they are hot. If theyare hot, do not open them – use an alternativeescape route.• Stay close to the floor. <strong>Smoke</strong> and hot gasesrise.• Cover your nose and mouth with a cloth (wetif possible). Take short, shallow breaths.• Keep doors and windows closed. Open themonly if you have to in order to escape.• Meet at your planned meeting place afterleaving the house. Carry out a headcount.• Call the Fire brigade on 999 as soon as possiblefrom outside your house. If possible use aneighbours phone or call box rather than amobile phone (as the location can be tracedfrom the number if the line is lost, or thebattery runs out for example).• Give the address and your name.• Never go back inside the building until amember of the fire service has told you it issafe to do so.Contact your local Fire Brigade. They will give youmore ideas about how to make your home saferfrom fires and how to plan your family’s escape.21


REPAIRDO NOT attempt to repair your <strong>FireAngel</strong>smoke alarm doing so will invalidate your warranty.If your smoke alarm is not operating properly, seethe next section ‘Troubleshooting’. If you cannotsolve the problem, please call the TechnicalSupport Line.If your <strong>FireAngel</strong> smoke alarm is no longer underwarranty, replace immediately with a comparable<strong>FireAngel</strong> brand smoke alarm.22


TROUBLESHOOTINGProblemYour <strong>FireAngel</strong> smoke alarm goes into alarm whenfirst connecting the batteryYour <strong>FireAngel</strong> smoke alarm does not test wheninstalledYour <strong>FireAngel</strong> smoke alarm chirps intermittentlySolution• SI-601 Only: Ionisation alarms can be affectedby high levels of static. It may be that the falsealarm has been caused by this when handlingthe alarm. Remove static that may have beentransferred to the alarm by wiping the frontcover with a slightly damp cloth.• Make sure you have removed the wrapperfrom the battery before reconnecting• Check the location of your smoke alarm (see‘Application & Positioning’).• Check that your smoke alarm is definitely thesource of chirping; make sure the noise isn’tcoming from another alarm (smoke/carbonmonoxide/gas/burglar alarm) by process ofelimination.• Replace battery. If the battery has beenrecently fitted and the chirping continuesthen contact technical support.23


Your <strong>FireAngel</strong> smoke alarm activates when nosmoke is visibleYou experience frequent unwanted alarms• Check the location of your smoke alarm (seethe section on ‘Positioning’).• Clean the smoke alarm (see the section on‘Routine Maintenance’).• For SI-601 smoke alarm only remove build-upof static electricity by wiping your <strong>FireAngel</strong>smoke alarm with a slightly damp cloth.• Check battery is correctly fitted, if the batteryhas been in service for more than 12 monthsreplace battery regardless.• Check the location of your <strong>FireAngel</strong> smokealarm (see the section on ‘Positioning’).• Clean the smoke alarm (see the section on‘Routine Maintenance’).• SI-601 Only: Remove buildup of staticelectricity by wiping your smoke alarm with aslightly damp cloth.• If the frequent unwanted alarms continuecontact technical support for advice.24


Your <strong>FireAngel</strong> smoke alarm does not sound duringtestingIf the alarm fails to operate correctly, the advice ofthe manufacturer should be sought• Make sure you push the test button firmly• If the unit has been silenced and is in lowsensitivity mode it may not test. Wait 15minutes then try again.• Replace battery. If the battery has beenrecently fitted and the alarm still fails to selftest then contact technical support.If you have any questions about the operationof your alarm, please contact the <strong>FireAngel</strong>Technical Support Team between 9am - 5pmMonday – Friday. Telephone: 024 7623 6663(1-800 523171 in Eire) or e-mail:technicalsupport@fireangel.co.ukYou can also visit the support section of ourwebsite www.fireangel.co.uk25


DISPOSALWARNING: DO NOT ATTEMPT TOOPEN.WARNING: DO NOT BURN.Waste electrical products should not be disposedof with household waste.Please recycle where facilities exist. Check withyour local authority, retailer or contact ourtechincal support team for recycling/disposaladvice as regional variations apply.The battery should be disconnected beforedisposal. You can also return your smoke alarm tous for disposal. For return address see the sectionon Returns. Please include a note confirming theproduct is being returned for disposal.26


HOW TO MAKE YOURHOME SAFERInstalling smoke alarms is only one step inprotecting your family from fires. You must alsotake steps to reduce the chances of fires startingin your home. If a fire does start, you must increaseyour chances of escaping.To have a good fire safety program you must:1 Install smoke alarms properly. Carefully followALL the instructions in this manual. Keep yoursmoke alarms clean, and test them everyweek.SMOKE ALARMS THAT DO NOT WORKWILL NOT ALERT YOU.2 Replace your smoke alarms immediately ifthey are not working properly.3 Follow fire safety rules, and preventhazardous situations:• Use smoking materials properly. Neversmoke in bed.• Keep matches and cigarette lighters awayfrom children.• Store flammable materials in propercontainers. Never use them near an openflame or sparks.• Keep electrical appliances and wiring in goodcondition. Do not overload electrical circuits.• Keep cookers, fireplaces, chimneys, andbarbecue grills grease free. Make surethey are properly installed, away from anycombustible materials.• Keep portable heaters and open flames suchas candles away from combustible materials.• Do not allow rubbish to accumulate insideyour home as this provides sources forcombustion.• Keep a supply of extra batteries on hand foryour battery powered <strong>Smoke</strong> <strong>Alarm</strong>s.4 Develop a family escape plan and practiceit with everyone in the household, includingsmall children if you have them.• Draw a floor plan of your home, and findtwo ways to exit from each room. There27


should be one way to get out of eachbedroom without opening the door, andalternate means of escape from an upperfloor in the event of the stairs being blocked(such as a fire escape).• Make sure everyone recognises the smokealarm signal and knows how to react to it.• If there are small children to consider it isimportant to explain to them what thesmoke alarm signal means. Teach them thatthey must be prepared to leave the homeby themselves if necessary. Show them howto check to see if doors are hot beforeopening them. Show them how to stay closeto the floor and crawl if necessary. Showthem how to use an alternative exit if thedoor is hot and should not be opened.• Decide on a meeting place a safe distancefrom your house. Again, if you have them,make sure that all your children understandthat they should go and wait for you there ifthere is a fire.• Hold fire drills at least every 6 months tomake sure that everyone, including smallchildren, know what to do to escape safely.• Know where to go to call the Fire Brigadefrom outside your home. Contact your localFire Brigade. They will give you more ideasabout how to make your home safer fromfires and how to plan your family’s escape.28


WARRANTY<strong>FireAngel</strong> Ltd warrants to the original purchaserthat its enclosed smoke alarm be free fromdefects in materials and workmanship undernormal residential use and service for a period of5 (five) years from the date of purchase in thecase of the SI-601 and SO-601 products. Providedit is returned with postage prepaid and proof ofpurchase date, <strong>FireAngel</strong> Ltd hereby warrants thatduring the 5 (five) year period commencing fromthe date of purchase in the case of the SI-601and SO-601 <strong>FireAngel</strong> Ltd, at its discretion, agreesto replace the unit free of charge. The warrantyon any replacement SI or SO range of alarm,will last for the remainder of the period of theoriginal warranty in respect of the alarm originallypurchased – that is from the date of originalpurchase and not from the date of receipt of thereplacement product. <strong>FireAngel</strong> Ltd reserves theright to offer an alternative product similar to thatbeing replaced if the original model is no longeravailable or in stock. This warranty applies to theoriginal retail purchaser from the date of originalretail purchase and is not transferable. Proof ofpurchase is required.This warranty does not cover damage resultingfrom accident, misuse, disassembly, abuse or lack ofreasonable care of the product, or applications notin accordance with the user manual. It does notcover events and conditions outside of <strong>FireAngel</strong>Ltd’s control, such as Acts of God (fire, severeweather etc.). It does not apply to retail stores,service centres or any distributors or agents.<strong>FireAngel</strong> Ltd will not recognise any changes tothis warranty by third parties.<strong>FireAngel</strong> Ltd shall not be liable for any incidentalor consequential damages caused by the breachof any expressed or implied warranty. Exceptto the extent prohibited by applicable law, anyimplied warranty of merchantability or fitnessfor a particular purpose is limited in duration for5(five) years for the SI-601 and SO-601 products.This warranty does not cover the battery, which isconsidered a user replaceable part. This warrantydoes not affect your statutory rights.29


RETURNSWe recommend that you contact the <strong>FireAngel</strong>Technical Support Line in the first instance on024 7623 6663, text phone users dial 18001 0247623 6663 or callers from Eire dial 1-800 523171.as we may be able to remedy the problem quicklyover the phone (this is to prevent unnecessaryreturns that take a longer time to process).Alternatively e-mail:technicalsupport@fireangel.co.uk.If there is a fault that we are unable to resolvethen our technical support team member willissue you with a returns authority number so thatyour product can be returned for testing.To return your <strong>FireAngel</strong> smoke alarm underwarranty, send it suitably packed and with thebattery disconnected with postage prepaid; anote indicating the returns authority number anddescribing the nature of the difficulty, with proofof purchase to:<strong>FireAngel</strong> LimitedThe TechnoCentrePuma WayCoventry, CV1 2TTUK30


PRODUCT RANGE<strong>FireAngel</strong> Ltd. manufacture an extensive rangeof home safety products including smoke alarms,carbon monoxide alarms, fire extinguishers andremote sounding devices. For more details visitwww.fireangel.co.uk.31


NOTES32Ref: SA0414/R3


SI-601SO-601Certificate No.651d/01to BS EN 14604:2005Certificate No.651d/04to BS EN 14604:2005Certified toBS EN 14604:2005Technical Support Line024 7623 6663 (1-800 523171 in Eire)E-mail:technicalsupport@fireangel.co.ukWeb:www.fireangel.co.uk<strong>FireAngel</strong> Ltd. The Technocentre, Puma Way, Coventry CV1 2TT UKRef: SA0414/R3