4. Specifications for BackfillingStructural Backfill used in the <strong>Utility</strong> <strong>Vault</strong> sides shall be of crushed and screened gravel or rock havingthe following Gradation Requirements when following ASTM C117 and C136 test methods:Sieve Size_mPer cent Passing112 000 10040 000 60 - 855 000 25 - 50315 5 - 1580 2 - 7Backfill against the structure shall be completed in layers no greater in depth than 300 mm and compactedto 95 % Standard Proctor. The backfill envelope around the structure should extend a minimum of 600mm around the <strong>Utility</strong> <strong>Vault</strong>’s perimeter. This operation is continued until the fill zone is at an elevation equalto the concrete deck of the <strong>Utility</strong> <strong>Vault</strong>.UTILITY VAULTINSTALLATION8U T I L I T Y V A U L T I N S T A L L A T I O N G U I D E