13.07.2015 Views

Harmonic detection and filtering - Schneider Electric

Harmonic detection and filtering - Schneider Electric

Harmonic detection and filtering - Schneider Electric

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Product selection according tomeasurement functionsPower MeterPM9P/PM9C PM500 PM700 PM700P PM710 PM810 PM820 PM850General selection criteriaInstallation On DIN rail Flush mount Flush mount Flush mountUse on LV distribution systems b b b b b b b bUse on LV <strong>and</strong> HV distribution systems - b b b b b b bCurrent / voltage accuracy 0.5 % 0.5 % 0.5 % 0.5 % 0.5 % 0.1 % 0.1 % 0.1 %Power / energy accuracy 2 % 1 % 1 % 1 % 1 % 1 % 0.5 % 0.5 %Instantaneous rms valuesCurrent b Phases b b b b b b b bb Neutral b b b b b b b bb Extended measurement range - - - - - - - -Voltage Phase-to-phase <strong>and</strong> phase-to-neutral b b b b b b b bFrequency b b b b b b b bTotal power b Active b b b b b b b bb Reactive b b b b b b b bb Apparent b b b b b b b bPower per phase b Active b b b b b b b bb Reactive b b b b b b b bb Apparent - b b b b b b bPower factor b Total b b b b b b b bb Per phase - b - - - b b bEnergy valuesActive energy b b b b b b b bReactive energy b b b b b b b bApparent energy - b b b b b b bUser-set accumulation mode - - - - - b b bDem<strong>and</strong> valuesCurrent Present <strong>and</strong> maximum values - b b b b b b bTotal active power Present <strong>and</strong> maximum values b b b b b b b bTotal reactive power Present <strong>and</strong> maximum values - b b b b b b bTotal apparent power Present <strong>and</strong> maximum values - b b b b b b bTotal predicted dem<strong>and</strong> kW, kVAR, kVA - - - - - b b bSynchronisation of calculation window - Option - - - b b bUser-set calculation mode - - b b b b b bPower quality measurementsTotal harmonic distortion b Voltage - b b b b b b bb Current - b b b b b b bIndividual harmonic content - - - - - - b bWaveform capture - - - - - - - bDetection of voltage sags <strong>and</strong> swells - - - - - - - -Programmable (logic <strong>and</strong> mathematical functions) - - - - - - - -Detection <strong>and</strong> capture of transients (< 1 µs) - - - - - - - -Flicker - - - - - - - -EN50160 compliance checking - - - - - - - -True rms measurement Maximum harmonic number 15 31 15 15 15 63 63 63Sampling rate Points per cycle - - 32 32 32 128 128 128(1) Measurement sensors included.38

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!