21Table 1. Value/range of experimental parametersParameterTested rangeFlow channelRectangular channelFlow directi<strong>on</strong>Horiz<strong>on</strong>talHydraulic diameter, mm 10.8Maximum c<strong>on</strong>densing length, m 2.87Steam temperature, °C 115-160Quality, % 10-80Heat flux, kW m 2 11.6-201Mass flux, kg m 2 s 20-50Pressure, kPa 170-620Reynolds number of liquid 910-2970Prandtl number of liquid 1.09-1.52Uncertainties for experimental results were determined by using <strong>the</strong> method of sequentialperturbati<strong>on</strong>, as outlined by Moffat [17] for single-sample data. Uncertainties in each of <strong>the</strong>independent variables used to calculate <strong>the</strong> heat transfer coefficient were estimated <strong>on</strong> <strong>the</strong> basisof calibrati<strong>on</strong> and examinati<strong>on</strong> of system/sensor interacti<strong>on</strong> errors. The uncertainties are