13.07.2015 Views

Covered Task - Kinder Morgan

Covered Task - Kinder Morgan

Covered Task - Kinder Morgan

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

G. Backfilling1. Be aware of OQ qualification requirements for backfilling the pipeline trench (<strong>Covered</strong> <strong>Task</strong> 104.11).H. Pressure monitoring1. Be aware of company procedures for pressure testing a relocated pipeline.I. Be aware of company procedures for proper documentation procedures.J. Be able to recognize and respond to abnormal operating conditions that might be encountered when performing this covered task.104.09 Inspection of clearance of existing pipe to underground structuresA. Be aware of KM policy on proximity of foreign crossing for physical clearanceB. Be aware of company policies for working in an excavation and for safe work permittingC. Be aware of possible cathodic interferences between structure and pipeline and know procedure for advising Corrosion Department of proposed clearance.D. Be aware of OQ qualification requirements for inspection of buried pipe (<strong>Covered</strong> <strong>Task</strong> 104.01).E. Be aware of company procedures for proper documentationF. Be able to recognize and respond to abnormal operating conditions that might be encountered when performing this covered task.104.10 Inspection of support structures on existing aboveground componentsA. Be able to inspect support structures according to manufacturer’s instructions and the local proceduresB. Be able to recognize and respond to abnormal operating conditions that might be encountered when performing this covered task104.11 Backfilling an excavationA. Inspection of backfill for damaging materials1. Be able to verify ditch is free of any debris.2. Be able to verify backfill material is acceptably free of rocks and debris.B. Protect pipe coating1. Be able to ensure pipe coating will not be damaged with backfilling the hole or when compacting backfill around pipe.2. In rocky soil, ensure a rock shield coating or equivalent protection is used.3. Be able to ensure compaction work does not damage pipe or coating.C. Ensure correct cover over pipeline, being aware of cover requirements in DOT Part 195D. Be aware of OQ qualification requirements for inspection of buried pipe when exposed (<strong>Covered</strong> <strong>Task</strong> 104.01)E. Be able to recognize and respond to abnormal operating conditions that might be encountered when performing this covered task.104.12 General pipeline repair – ClockspringA. Be aware that all Company health and safety guidelines (safe work permit) must be met prior to commencement of workB. Be aware that installation of Clockspring device requires vendor training and certificationC. Be familiar with Company procedures for working safely in an excavationD. Be aware of OQ qualifications for coating removal and pipeline surface preparation prior to application of repair material and coating repair after installation ofClockspring (<strong>Covered</strong> <strong>Task</strong> 102.13).Page 21 of 33

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!