13.07.2015 Views

Technical guidelines on testing the migration of primary aromatic ...

Technical guidelines on testing the migration of primary aromatic ...

Technical guidelines on testing the migration of primary aromatic ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

The simulant from <strong>the</strong> first and sec<strong>on</strong>d test is discarded. The samples should <strong>the</strong>nbe subjected to <strong>the</strong> third migrati<strong>on</strong> test but individually (1 article in 1 beaker).Exposure 1 Exposure 2 Exposure 3Do not analysesimulantDo not analysesimulantAnalysesimulantThe three porti<strong>on</strong>s <strong>of</strong> simulant derived from exposure 3 should be tested for migrati<strong>on</strong><strong>of</strong> formaldehyde.Melamine kitchenware articles that require <strong>testing</strong> by fillingEach test specimen is filled to 0.5 cm below <strong>the</strong> rim and exposed to <strong>the</strong> simulant.The simulant is removed and a sec<strong>on</strong>d and third successive migrati<strong>on</strong> testsperformed in <strong>the</strong> same way. The simulant from <strong>the</strong> first and sec<strong>on</strong>d test can bediscarded.Exposure 1 Exposure 2 Exposure 3Do not analysesimulantDo not analysesimulantAnalysesimulantThe three porti<strong>on</strong>s <strong>of</strong> simulant derived from exposure 3 should be tested forformaldehyde.7.6.2 Lot(s) <strong>of</strong> sets <strong>of</strong> articlesA lot <strong>of</strong> grouped articles sold in sets (e.g. with different shapes in <strong>on</strong>e set)Polyamide kitchenware articles that require <strong>testing</strong> by immersi<strong>on</strong>The three sets <strong>of</strong> test specimens for <strong>the</strong> migrati<strong>on</strong> test are tested toge<strong>the</strong>r in <strong>on</strong>ebeaker for <strong>the</strong> first exposure as shown below and <strong>the</strong> simulant is analysed for PAAs.If <strong>the</strong> test specimens are compliant in this first test assuming that all <strong>of</strong> <strong>the</strong> PAAsmeasured in <strong>the</strong> simulant have migrated from <strong>the</strong> article with <strong>the</strong> smallest surfacearea (i.e. <strong>the</strong> worst case), <strong>the</strong>n no fur<strong>the</strong>r <strong>testing</strong> is required.Note: Migrati<strong>on</strong> tests are normally c<strong>on</strong>ducted three times for repeat use articles, and <strong>the</strong> results <strong>of</strong><strong>the</strong> third migrati<strong>on</strong> taken into account. However, <strong>the</strong> migrati<strong>on</strong> <strong>of</strong> PAAs is known to decrease after<strong>the</strong> first migrati<strong>on</strong>, <strong>the</strong>refore in this scheme <strong>the</strong> simulant from <strong>the</strong> 1 st migrati<strong>on</strong> is analysed for PAAsand if results are compliant <strong>the</strong>n no fur<strong>the</strong>r <strong>testing</strong> is required.If <strong>the</strong> sample sets are not compliant a sec<strong>on</strong>d exposure should be carried out in <strong>the</strong> same way (i.e.<strong>the</strong> three sets <strong>of</strong> test specimens exposed toge<strong>the</strong>r in <strong>on</strong>e beaker).13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!