30HZ/HZV 043-280 Water-Cooled/Condenserless Liquid Chillers
30HZ/HZV 043-280 Water-Cooled/Condenserless Liquid Chillers
30HZ/HZV 043-280 Water-Cooled/Condenserless Liquid Chillers
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
4.4 - Electrical data (R22)<strong>30HZ</strong>/<strong>HZV</strong> <strong>043</strong> 052 065 091 101 111 121 141 161 195 225 250 <strong>280</strong>Power wiringNominal power supply V-ph-Hz 400-3-50System voltage range V 360-440Control circuit power supplyThe control circuit is supplied via a factory-installed transformer.Nominal operating power input*kW<strong>30HZ</strong> 35.8 45.5 64 64 72 80 85 104 122 154 189 224 253<strong>30HZ</strong>V 38.1 48 65 69 76 85 93 111 133 164 198 233 264Nominal operating current*A<strong>30HZ</strong> 59.4 75.5 106 106 119 133 141 172 202 255 313 372 418<strong>30HZ</strong>V 63.2 79.6 108 114 126 141 154 184 221 272 328 387 438Maximum operating power input**kW<strong>30HZ</strong> – circuit A and B 46 55 79 83 91 101 111 134 158 198 237 - -<strong>30HZ</strong> – circuit A - - - - - - - - - - - 158 158<strong>30HZ</strong> – circuit B - - - - - - - - - - - 119 158<strong>30HZ</strong>V – circuit A and B 54 65 90 98 107 119 130 155 180 225 270 - -<strong>30HZ</strong>V – circuit A - - - - - - - - - - - 180 180<strong>30HZ</strong>V – circuit B - - - - - - - - - - - 135 180Maximum operating current (Un-10%)***A<strong>30HZ</strong> – circuit A and B 88 107 153 161 177 195 214 260 305 382 458 - -<strong>30HZ</strong> – circuit A - - - - - - - - - - - 305 305<strong>30HZ</strong> – circuit B - - - - - - - - - - - 229 305<strong>30HZ</strong>V – circuit A and B 101 123 170 185 203 224 246 293 340 425 509 - -<strong>30HZ</strong>V – circuit A - - - - - - - - - - - 340 340<strong>30HZ</strong>V – circuit B - - - - - - - - - - - 255 340Maximum operating current (Un)***A<strong>30HZ</strong> – circuit A and B 79 96 137 145 159 176 193 234 275 343 412 - -<strong>30HZ</strong> – circuit A - - - - - - - - - - - 275 275<strong>30HZ</strong> – circuit B - - - - - - - - - - - 206 275<strong>30HZ</strong>V circuit A and B 91 111 153 166 182 202 221 264 306 382 458 - -<strong>30HZ</strong>V circuit A - - - - - - - - - - - 306 306<strong>30HZ</strong>V circuit B - - - - - - - - - - - 229 306Maximum unit starting current (Un)†A<strong>30HZ</strong> – circuit A and B 183 199 274 246 229 277 293 333 408 475 542 - -<strong>30HZ</strong> – circuit A - - - - - - - - - - - 408 408<strong>30HZ</strong> – circuit B - - - - - - - - - - - 341 408<strong>30HZ</strong>V – circuit A and B 188 207 283 263 251 299 318 360 436 513 589 - -<strong>30HZ</strong>V – circuit A - - - - - - - - - - - 436 436<strong>30HZ</strong>V – circuit B - - - - - - - - - - - 360 436<strong>30HZ</strong> Ratio max. starting current/max. current, circ. A A 2.3 2.07 1.99 1.7 1.44 1.57 1.52 1.43 1.49 1.38 1.32 1.49 1.49<strong>30HZ</strong> Ratio max. starting current/max. current, circ. B A - - - - - - - - - - - 1.66 1.49<strong>30HZ</strong>V Ratio max. starting current/max. current, circ. A A 2.06 1.87 1.85 1.58 1.37 1.48 1.44 1.37 1.43 1.34 1.28 1.43 1.43<strong>30HZ</strong>V Ratio max. starting current/max. current, circ. B A - - - - - - - - - - - 1.57 1.43Holding current for three-phase short circuitskA<strong>30HZ</strong> – circuit A and B 15 15 15 15 20 20 20 20 20 25 25 - -<strong>30HZ</strong> – circuit A - - - - - - - - - - - 25 25<strong>30HZ</strong> – circuit B - - - - - - - - - - - 25 25<strong>30HZ</strong>V – circuit A and B 15 15 15 15 20 20 20 20 20 25 25 - -<strong>30HZ</strong>V – circuit A - - - - - - - - - - - 25 25<strong>30HZ</strong>V – circuit B - - - - - - - - - - - 25 25Customer unit standby power for evaporator andcondenser pump connections‡ACircuit A 6 8 10 10 10 10 10 12 15 24 32 25 32Circuit B - - - - - - - - - - - 20 20* Standard Eurovent conditions: Evaporator entering/leaving water temperature 12°C/7°C, condenser entering/leaving water temperature 30°C/35°C.Nominal operating power input: unit power input (compressors, control) plus the capacity corresponding to the evaporator and condenser pressure drop (flow x drop/0.3).** Power input, compressors, at unit operating limits (saturated evaporating temperature (dew point) = 12°C, saturated condensing temperature (dew point) = 53°C(<strong>30HZ</strong>)/68°C (<strong>30HZ</strong>V), and a nominal voltage of 400 V (data given on the unit name plate).*** Maximum unit operating current at maximum unit power input.† Maximum instantaneous starting current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced starting current of the largestcompressor).‡ Current and power inputs not included in the values above.12