Measuring condition (For <strong>DMC</strong>-FT20, <strong>DMC</strong>-TS20)*Attach "L" size of absorption pad.[Exhaust Air]5. Operate the measurement switch of the air-leak tester to exhaust air inside the product for 90 seconds.[Stand-by]6. After a laps of 15 seconds, take a note (Record) that the pressure value indicated on the indication panel.[Measurement]7. Confirm that the pressure value fluctuations during measurement process are within the testing specification.The air-leak test is now completed.3. Packing replacement record input:• To enter the repair record, it is necessary to use the "DIAS" software. The maintenance software "DIAS" is available at "TSNWebsite".To download, click on "Support Information from NWBG/VDBG-AVC".*DIAS (DSC Integrated Assist Software)31