13.07.2015 Views

District of Saanich, Building and Plumbing Bylaw 8627

District of Saanich, Building and Plumbing Bylaw 8627

District of Saanich, Building and Plumbing Bylaw 8627

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Building</strong> <strong>and</strong> <strong>Plumbing</strong> <strong>Bylaw</strong>, 2005, No. <strong>8627</strong>2.4.1 The Manager <strong>of</strong> Inspection Services may enter any property or premises at anyreasonable time for the purpose <strong>of</strong> administering or enforcing this bylaw, or if thereis reason to believe an unsafe condition exists.2.4.2 (1) The Manager <strong>of</strong> Inspection Services may order:(a) a person who contravenes this bylaw to comply with it within the time periodspecified;(b) work to stop on the building or any part there<strong>of</strong> if such work is proceeding incontravention <strong>of</strong> this bylaw, or if there is deemed to be an unsafe condition,by placing a "Stop Work" notice or by written notice;(c) the removal <strong>of</strong> any unauthorized encroachment on public property;(d) the removal <strong>of</strong> any building or part there<strong>of</strong> constructed in contravention <strong>of</strong>this bylaw;(e) the cessation <strong>of</strong> any occupancy in contravention <strong>of</strong> this bylaw;(f) the cessation <strong>of</strong> any occupancy if any unsafe condition exists because <strong>of</strong>work being undertaken or not completed; <strong>and</strong>(g) correction <strong>of</strong> any unsafe condition.2.4.3 The Manager <strong>of</strong> Inspection Services may direct that tests <strong>of</strong> materials, equipment,devices, construction methods, structural assemblies or foundation conditions bemade, or sufficient evidence or pro<strong>of</strong> be submitted at the expense <strong>of</strong> the owner,where such evidence or pro<strong>of</strong> is necessary to determine whether the material,equipment, device, construction or foundation condition complies with this bylaw.2.4.4 (1) Where the site conditions, the size or complexity <strong>of</strong> a building, part <strong>of</strong> a buildingor building component warrant, the Manager <strong>of</strong> Inspection Services may require:(a) pr<strong>of</strong>essional design <strong>and</strong> field review; <strong>and</strong>(b) that the appropriate Letters <strong>of</strong> Assurance, Schedules A, B-1, B-2, C-A <strong>and</strong>C-B as contained in the <strong>Building</strong> Code be submitted by the owner.(2) Without limiting the generality <strong>of</strong> Subsection 2.4.4 (1), the following shall requirepr<strong>of</strong>essional design <strong>and</strong> field review:(a) buildings that fall within the scope <strong>of</strong> Part 3 <strong>of</strong> the <strong>Building</strong> Code;Page 13 <strong>of</strong> 33

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!