EM 1110-3-17211 May 84e . Capacity factor . A capacity factor is used to make allowancesfor population variation, changes in sewage characteristics, andunusual peak flows . The design population is arrived at by multiplyingthe actual authorized Army and civilian personnel population by theappropriate capacity factor . Total personnel is the sum of residentpersonnel plus one-third the nonresident personnel . For a residentpopulation of 10,000 and nonresident population of 3,000 persons, totalpersonnel would equal 11,000 ( = 10,000 + 3,000/3), capacity factorwould be 1 .25, and design population would be 13,750 (= 11,000 x 1 .25) .Capacity factors for various levels of actual total personnel are givenin table 4-2 .Table 4-2 .Total PersonnelCapacity FactorsCapaci ty Factor4-4 . Volume of wastewater .5,000 or less 1 .5010,000 1 .2520,000 1 .1530,000 1 .1040,000 1 .0550,000 or more 1 .00a . Variations in wastewater flow . The rates of sewage flow at Armyinstallations vary widely throughout the day . The design of processelements in a sewage treatment plant is based on the average hourlyrate of flow . Transmission elements, such as conduits, siphons, anddistributor mechanisms, will be designed on the basis of an expectedpeak rate of flow of three times the average rate . Consideration ofthe minimum rate of flow is necessary in the design of certainelements, such as measuring devices and dosing equipment . For thispurpose, 40 percent of the average flow rate will be used .b . Average wastewater flow . The average wastewater flow to be usedin the design of new treatment plants will be computed by multiplyingthe total tributary population by the per capita rates of flowdetermined from 4-3 .b . (applying the appropriate capacity factor fromtable 4-2), and then adjusting for such factors as industrialwastewater flow, storm water flow, and infiltration . Where shiftpersonnel are engaged, the flow will be computed for the shift whenmost of the people are engaged . Good practice requires exclusion ofstorm water from the sanitary sewage system to the maximum practicalextent . Infiltration must also be kept to a minimum . Both must becarefully analyzed, and the most realistic practical quantity that canbe used in design must be assigned to these flows . Average wastewaterflow is usually expressed in mgd, but will be calculated to theappropriate units for design of the unit process under consideration .4-2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!