13.07.2015 Views

Pricing Guide for Horizontal Above NEMA Motors - Siemens Industry ...

Pricing Guide for Horizontal Above NEMA Motors - Siemens Industry ...

Pricing Guide for Horizontal Above NEMA Motors - Siemens Industry ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Pricing</strong> <strong>Guide</strong> <strong>for</strong> <strong>Horizontal</strong> <strong>Above</strong> <strong>NEMA</strong> <strong>Motors</strong> ANSP-60000-1112Base List Prices, Frame, and FeaturesTEFC Enclosure per IEEE 841 Std- 2009(Order Code R61 / Category 2)Section 1Part 5BPage 1Date 11/12AC Squirrel-Cage Induction1.0 Service FactorClass F Insulation80 deg. C Rise by Resistance40 deg. C AmbientThis specification addresses motor requirements on TEFC, anti-friction bearing motors through 500 HP. The Basic ListPrices in the following tables include special features of this specification which are but not limited to; IP55 degree of protection which includes rotating shaft seals to provide maximum protection against contaminantsentering the motor along the shaft Minimum guaranteed full load efficiency per IEEE 841 Table 2 (See General Comment #2) Cast iron fan housing Corrosion protection of rotor Alemite grease fittings Precision balance Maximum bearing temperature limits of 50C <strong>for</strong> 2-pole, 45C <strong>for</strong> 4-pole and slower Frame breather-drain Sealed leads between motor and terminal box Max. shaft indicator reading of 0.0015-in. <strong>for</strong> direct-connected, 0.002-in. if belt drive Motor foot flatness not to exceed 0.005-in. Special nameplate and auxiliary tags Testing per paragraph 9.2General Comments to IEEE 841- 2009All proposals to must contain the following comments in addition to any other applicable comments and/or exceptionsalready taken and depending upon the quotation request;1. Para 6.8: Taking exception to 90 dbA sound power level. Quoting typical sound pressure level in dBA asmeasured per <strong>NEMA</strong> MG1, Part 9 at 3 feet and at no load. Consult factory <strong>for</strong> lower noise options.2. Para 8.0: The minimum and nominal full load efficiencies per Table 2 are based upon efficiency evaluation perIEEE 112-2004, Methods E1 or F1 with assumed stray load loss.Include Comment 3 if space heaters are quoted as a base feature or option3. Para. 11.b: Taking exception and quoting space heaters with 160 deg. C maximum sheath temperature.Include Comment 4 if motor if a hazardous location is not specified4. Para 3.1.e: Motor offered is based on a non-hazardous area application.Include Comment 5 if motor is not direct-connected and is to be V-belt drive5. Para 6.1.d: Taking exception and quoting L10 life of 17,500 hours pending receipt and review of motor and drivensheave sizes as well as the size, type and number of belts.Include Comment 6 if motor is 2-pole (3600 or 3000 RPM)6. Para 6.9: Taking exception and quoting maximum vibration of 0.10 ips unfiltered as measured on the bearinghousing.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!