Pricing Guide for Horizontal Above NEMA Motors - Siemens Industry ...
Pricing Guide for Horizontal Above NEMA Motors - Siemens Industry ...
Pricing Guide for Horizontal Above NEMA Motors - Siemens Industry ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Pricing</strong> <strong>Guide</strong> <strong>for</strong> <strong>Horizontal</strong> <strong>Above</strong> <strong>NEMA</strong> <strong>Motors</strong> ANSP-60000-1112Base List Prices, Frame, and FeaturesTEFC Enclosure per IEEE 841 Std- 2009(Order Code R61 / Category 2)Section 1Part 5BPage 1Date 11/12AC Squirrel-Cage Induction1.0 Service FactorClass F Insulation80 deg. C Rise by Resistance40 deg. C AmbientThis specification addresses motor requirements on TEFC, anti-friction bearing motors through 500 HP. The Basic ListPrices in the following tables include special features of this specification which are but not limited to; IP55 degree of protection which includes rotating shaft seals to provide maximum protection against contaminantsentering the motor along the shaft Minimum guaranteed full load efficiency per IEEE 841 Table 2 (See General Comment #2) Cast iron fan housing Corrosion protection of rotor Alemite grease fittings Precision balance Maximum bearing temperature limits of 50C <strong>for</strong> 2-pole, 45C <strong>for</strong> 4-pole and slower Frame breather-drain Sealed leads between motor and terminal box Max. shaft indicator reading of 0.0015-in. <strong>for</strong> direct-connected, 0.002-in. if belt drive Motor foot flatness not to exceed 0.005-in. Special nameplate and auxiliary tags Testing per paragraph 9.2General Comments to IEEE 841- 2009All proposals to must contain the following comments in addition to any other applicable comments and/or exceptionsalready taken and depending upon the quotation request;1. Para 6.8: Taking exception to 90 dbA sound power level. Quoting typical sound pressure level in dBA asmeasured per <strong>NEMA</strong> MG1, Part 9 at 3 feet and at no load. Consult factory <strong>for</strong> lower noise options.2. Para 8.0: The minimum and nominal full load efficiencies per Table 2 are based upon efficiency evaluation perIEEE 112-2004, Methods E1 or F1 with assumed stray load loss.Include Comment 3 if space heaters are quoted as a base feature or option3. Para. 11.b: Taking exception and quoting space heaters with 160 deg. C maximum sheath temperature.Include Comment 4 if motor if a hazardous location is not specified4. Para 3.1.e: Motor offered is based on a non-hazardous area application.Include Comment 5 if motor is not direct-connected and is to be V-belt drive5. Para 6.1.d: Taking exception and quoting L10 life of 17,500 hours pending receipt and review of motor and drivensheave sizes as well as the size, type and number of belts.Include Comment 6 if motor is 2-pole (3600 or 3000 RPM)6. Para 6.9: Taking exception and quoting maximum vibration of 0.10 ips unfiltered as measured on the bearinghousing.