13.07.2015 Views

Lista mensal documentos normativos - IPQ

Lista mensal documentos normativos - IPQ

Lista mensal documentos normativos - IPQ

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

DOCUMENTOS<strong>normativos</strong>Data Limite: 2010-10-29SR 42FprEN 60060-2:2010High-voltage test techniques Part 2: Measuring systems(IEC 60060-2:201X)Data Limite: 2010-11-05SR 46FprEN 62037-1:2010Passive r.f. and microwave devices, intermodulationlevel measurement Part 1: General requirements andmeasuring methods(IEC 62037-1:201X)Data Limite: 2010-10-15SR 46FprEN 62037-1:2010Passive r.f. and microwave devices, intermodulationlevel measurement Part 1: General requirements andmeasuring methods(IEC 62037-1:201X)Data Limite: 2010-10-15SR 46FprEN 62037-2:2010Passive r.f. and microwave devices, intermodulationlevel measurement Part 2: Measurement of passiveintermodulation in coaxial cable assemblies(IEC 62037-2:201X)Data Limite: 2010-10-15SR 46FprEN 62037-2:2010Passive r.f. and microwave devices, intermodulationlevel measurement Part 2: Measurement of passiveintermodulation in coaxial cable assemblies(IEC 62037-2:201X)Data Limite: 2010-10-15SR 46FprEN 62037-3:2010Passive r.f. and microwave devices, intermodulationlevel measurement Part 3: Measurement of passiveintermodulation in coaxial connectors(IEC 62037-3:201X)Data Limite: 2010-10-15SR 46FprEN 62037-3:2010Passive r.f. and microwave devices, intermodulationlevel measurement Part 3: Measurement of passiveintermodulation in coaxial connectors(IEC 62037-3:201X)Data Limite: 2010-10-15SR 46FprEN 62037-4:2010Passive r.f. and microwave devices, intermodulationlevel measurement Part 4: Measurement of passiveintermodulation in coaxial cables(IEC 62037-4:201X)Data Limite: 2010-10-15SR 46FprEN 62037-4:2010Passive r.f. and microwave devices, intermodulationlevel measurement Part 4: Measurement of passiveintermodulation in coaxial cables(IEC 62037-4:201X)Data Limite: 2010-10-15Publicação oficial do <strong>IPQ</strong>, enquanto Organismo Nacional de NormalizaçãoSR 46FprEN 62037-5:2010Passive r.f. and microwave devices, intermodulationlevel measurement Part 5: Measurement of passiveintermodulation in filters(IEC 62037-5:201X)Data Limite: 2010-10-15SR 46FprEN 62037-5:2010Passive r.f. and microwave devices, intermodulationlevel measurement Part 5: Measurement of passiveintermodulation in filters(IEC 62037-5:201X)Data Limite: 2010-10-15SR 46FprEN 62037-6:2010Passive r.f. and microwave devices, intermodulationlevel measurement Part 6: Measurement of passiveintermodulation in antennas(IEC 62037-6:201X)Data Limite: 2010-10-15SR 46FprEN 62037-6:2010Passive r.f. and microwave devices, intermodulationlevel measurement Part 6: Measurement of passiveintermodulation in antennas(IEC 62037-6:201X)Data Limite: 2010-10-15SR 47FprTR 62258-4:2010Semiconductor die products Part 4: Questionnaire for dieusers and suppliers(IEC/TR 62258-4:201X)Data Limite: 2010-11-05SR 47FprEN 60191-6-5:2010Mechanical standardization of semiconductor devices Part6-5: General rules for the preparation of outlinedrawings of surface mounted semiconductor devicepackage - Design guide for fine-pitch ball grid array(FBGA)(IEC 60191-6-5:201X)Data Limite: 2011-01-28SR 47EFprEN 60747-15:2010Semiconductor devices - Discrete devices Part 15:Isolated power semiconductor devices(IEC 60747-15:201X)Data Limite: 2010-11-26SR 47EFprEN 60747-16-5:2010Semiconductor devices Part 16-5: Microwave integratedcircuits - Oscillators(IEC 60747-16-5:201X)Data Limite: 2011-02-25SR 47FprEN 60749-15:2010Semiconductor devices - Mechanical and climatic testmethods Part 15: Resistance to soldering temperaturefor through-hole mounted devices(IEC 60749-15:200X)Data Limite: 2010-10-15SR 47FprEN 60749-34:2010Semiconductor devices - Mechanical and climatic test<strong>Lista</strong> <strong>mensal</strong> ▪ <strong>documentos</strong> <strong>normativos</strong> imp DNOR-01-06 56 14 Outubro 2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!