13.07.2015 Views

Series SV - SMC ETech

Series SV - SMC ETech

Series SV - SMC ETech

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Flat Ribbon Cable Connector <strong>Series</strong> <strong>SV</strong>How to Order Valve Manifold AssemblyOrdering example (<strong>SV</strong>1000)ManifoldSS5V1-16PD1-06B-C6 (1 set)Double solenoid<strong>SV</strong>1200-5FU (2 sets)Single solenoid<strong>SV</strong>1100-5FU (4 sets)U sideStationsD D D D D D3 2 1Type of actuation12345AB<strong>SV</strong> 1 100 – 5 F –<strong>Series</strong>1 <strong>SV</strong>10002 <strong>SV</strong>20003 <strong>SV</strong>30004 <strong>SV</strong>4000D side2 position single solenoid2 position double solenoid3 position closed center3 position exhaust center3 position pressure center4 position dual 3 port valve: N.C./N.C.4 position dual 3 port valve: N.O./N.O.4 position dual 3 port valve: N.C./N.O.C∗ 4 position dual 3 port valves areapplicable to <strong>Series</strong> <strong>SV</strong>1000 and<strong>SV</strong>2000 only.Pilot typeNil Internal pilotR External pilot∗ External pilot specificationsis not available for 4 positiondual 3 port valves.How to Order Solenoid ValvesSS5V1-16PD1-06B-C6··········1 set (manifold part no.)∗<strong>SV</strong>1100-5FU······4 sets (Single solenoid part no.)∗<strong>SV</strong>1200-5FU······2 sets (Double solenoid part no.)Rated voltage5624 VDC12 VDCBack pressure check valveNote) Available with manifold blockfor station additions. Refer topages 1-2-89 and 1-2-93.Manual overrideNil: Non-locking pushtypeD: Push-turn lockingslotted typeLight/Surge voltage suppressorURNote)With light/surge voltage suppressorWith surge voltage suppressorNil NoneK Built-in∗ Built-in back pressure check valve type is applicable to series <strong>SV</strong>1000 only.∗ Back pressure check valve is not available for 3 position closed center and 3position pressure center.Refer to Precautions 2 on page 1-2-9.<strong>SV</strong>SZSYSYJSXA, B port size (Metric)A, B port size (Inch)SymbolC3A, B portOne-touch fitting for ø3.2P, E port Applicable series SymbolN1A, B portC4 One-touch fitting for ø4One-touch<strong>SV</strong>1000 N3fitting for ø8C6 One-touch fitting for ø6N7C4 One-touch fitting for ø4N3One-touchC6 One-touch fitting for ø6<strong>SV</strong>2000 N7fitting for ø10C8 One-touch fitting for ø8N9C6 One-touch fitting for ø6N7One-touchC8 One-touch fitting for ø8<strong>SV</strong>3000 N9fitting for ø12C10 One-touch fitting for ø10N11C8 One-touch fitting for ø8N9One-touchC10 One-touch fitting for ø10N11fitting for ø12C12 One-touch fitting for ø1202N02 Rc 1/4<strong>SV</strong>4000 03NRc 3/803 Rc 3/802T02F G 1/403T NPTF 3/8G 3/803F G 3/8MMA, B ports mixedOne-touch fitting for ø1/8"One-touch fitting for ø5/32"One-touch fitting for ø1/4"One-touch fitting for ø5/32"One-touch fitting for ø1/4"One-touch fitting for ø5/16"One-touch fitting for ø1/4"One-touch fitting for ø5/16"One-touch fitting for ø3/8"One-touch fitting for ø5/16"One-touch fitting for ø3/8"NPT 1/4NPT 3/8NPTF 1/4P, E port Applicable seriesOne-touchfitting for ø5/16"One-touchfitting for ø3/8"One-touchfitting for ø3/8"One-touchfitting for ø3/8"NPT 3/8NPTF 3/8A, B ports mixed<strong>SV</strong>1000<strong>SV</strong>2000<strong>SV</strong>3000<strong>SV</strong>4000∗ In the case of mixed specifications(M), indicate separately on themanifold specification sheet.∗ Port sizes of X, PE port for externalpilot specification (R, RS) are ø4(metric), ø5/32" (inch) for<strong>SV</strong>1000/2000 and ø6(metric) andø1/4" (inch) for <strong>SV</strong>3000/4000.1-2-77

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!