13.07.2015 Views

Series SV - SMC ETech

Series SV - SMC ETech

Series SV - SMC ETech

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Series</strong> <strong>SV</strong>Manifold Electrical Wiring10P/16P Flat Ribbon Cable Type (26 pins)10PG/16PG Flat Ribbon Cable Type (20 pins)Light/Surge voltagesuppressorLight/Surge voltagesuppressorLight/Surge voltagesuppressorLight/Surge voltagesuppressor2625242322214321CommonCommonSOL.BSOL.ASOL.BSOL.AStation 12Station 11SOL.BStation 2SOL.ASOL.BStation 1SOL.ATriangle markLight/Surge voltagesuppressorLight/Surge voltagesuppressorLight/Surge voltagesuppressorLight/Surge voltagesuppressor2019181716154321CommonCommonSOL.BSOL.ASOL.BSOL.ASOL.BSOL.AStation 9Station 8Station 2SOL.BStation 1SOL.ATriangle mark• This circuit has double wiring specifications for up to 12 stations. Since theusable number of solenoids differs depending on the manifold type, referto the table below. In the case of single solenoids, connect to SOL. A.Furthermore, when wiring is specified on a manifold specification sheet,connections are made without skipping any connectors, and connectionsare made without skipping any connectors, and signals A for single and A,B for double are in order 1 2 3 4, etc.• Stations are counted from D side (connector side) as the 1st one.• Since terminal numbers are not indicated on the flat cable, use the trianglemark as a reference for wiring.• Since solenoid valves do not have polarity, either the +COM or –COM canbe used.Usable No. of SolenoidsModelMax. no. of solenoids<strong>SV</strong>1000Tie-rod base type 10 to24<strong>SV</strong>4000Cassette base type 16<strong>SV</strong>1000<strong>SV</strong>20001824• This circuit has double wiring specifications for up to 9 stations. Since theusable number of solenoids differs depending on the manifold type, referto the table below. In the case of single solenoids, connect to SOL. A.Furthermore, when wiring is specified on a manifold specification sheet,connections are made without skipping any connectors, and connectionsare made without skipping any connectors, and signals A for single and A,B for double are in order 1 2 3 4, etc.• Stations are counted from D side (connector side) as the 1st one.• Since terminal numbers are not indicated on the flat cable, use the trianglemark as a reference for wiring.• Since solenoid valves do not have polarity, either the +COM or –COM canbe used.Usable No. of SolenoidsModelMax. no. of solenoids<strong>SV</strong>1000Tie-rod base type 10 to<strong>SV</strong>4000 18<strong>SV</strong>1000Cassette base type 16<strong>SV</strong>200010PH/16PH Flat Ribbon Cable Type (10 pins)109CommonCommonLight/Surge voltagesuppressor87SOL.BSOL.AStation 4Light/Surge voltagesuppressorLight/Surge voltagesuppressorLight/Surge voltagesuppressor4231SOL.BSOL.AStation 2SOL.BStation 1SOL.ATriangle mark• This circuit has double wiring specifications for up to 4 stations. Since theusable number of solenoids differs depending on the manifold type, referto the table below. In the case of single solenoids, connect to SOL. A.Furthermore, when wiring is specified on a manifold specification sheet,connections are made without skipping any connectors, connections aremade without skipping any connectors, and signals A for single and A, Bfor double are in order 1 2 3 4, etc.• Stations are counted from D side (connector side) as the 1st one.• Since terminal numbers are not indicated on the flat cable, use the trianglemark as a reference for wiring.• Since solenoid valves do not have polarity, either the +COM or –COM canbe used.Usable No. of SolenoidsModelMax. no. of solenoids<strong>SV</strong>1000Tie-rod base type 10 to<strong>SV</strong>4000 8<strong>SV</strong>1000Cassette base type 16<strong>SV</strong>20001-2-78

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!