13.07.2015 Views

Series SV - SMC ETech

Series SV - SMC ETech

Series SV - SMC ETech

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Series</strong> <strong>SV</strong> 1/4, 3/8 thread type port block assemblyFor A, B portSY9000 – 58A –0203For P, E portSY9000 – 58B – 03B 2AThread typeNilFNTRcGNPTNPTFNote 1) Be careful to avoid damage or contamination of O-rings, as this can cause air leakage.Note 2) When removing a fitting assembly from a valve, after removing the clip, attach tubing or a plug (KQP-)to the One-touch fitting, and pull it out while holding the tubing (or plug). If it is pulled out while holding therelease button of the fitting assembly (resin part), the release button may be damaged.However, 02 and 03 port block assemblies should be pulled out as they are.Note 3) Be sure to shut off the power and air supplies before disassembly. Furthermore, since air may remaininside the actuator, piping and manifold, confirm that the air is completely exhausted before performing anywork.4ClipP B B B BO-ringFitting assembly<strong>SV</strong>SZSYSYJSX How to order tie-rod type 10 solenoid valves with manifold block[<strong>Series</strong> <strong>SV</strong>1000 to <strong>SV</strong>4000]• Type with manifold block is used when adding stations, etc.<strong>SV</strong> 1 100 – 5 F – –<strong>Series</strong>1 <strong>SV</strong>10002 <strong>SV</strong>20003 <strong>SV</strong>30004 <strong>SV</strong>4000Type of actuation1 2 position single solenoid2 2 position double solenoid3 3 position closed center4 3 position exhaust center5 3 position pressure centerA 4 position dual 3 port valve: N.C./N.C.B 4 position dual 3 port valve: N.O./N.O.C 4 position dual 3 port valve: N.C./N.O.∗ 4 position dual 3 port valves areapplicable to <strong>Series</strong> <strong>SV</strong>1000 and<strong>SV</strong>2000 only.Pilot typeNil Internal pilotR External pilot∗ External pilot specificationsis not available for 4 positiondual 3 port valves.Back pressure check valveNil NoneK Built-in∗ Built-in back pressurecheck valve type isapplicable to series<strong>SV</strong>1000 only.∗ Back pressure checkvalve is not available for 3position closed center and3 position pressure center.Refer to Precautions 2on page 1-2-9.Rated voltage5624 VDC12 VDCManual overrideNil: Non-locking push typeLight/Surge voltage suppressorUR∗ Note that serial wiring(EX500, EX250 andEX120) are only availablewith 24 VDC.Manifold wiring specificationsNilSDouble wiringSingle wiringManifold block typeFor Tie-rod base type 10 withTmanifold blockNote) Tie-rod type 10 includes tie-rodsfor station additions.With light/surge voltage suppressorWith surge voltage suppressorA, B port sizeRefer to A, B port size table onpages 1-2-20, 36, 44, and 76.D: Push-turn locking slottedtypeExample (<strong>SV</strong>1000)<strong>SV</strong>1200-5FU-T-C6D1-2-93

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!