13.07.2015 Views

Coral MIS System.PDF - Integra LifeSciences

Coral MIS System.PDF - Integra LifeSciences

Coral MIS System.PDF - Integra LifeSciences

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Integra</strong> <strong>Coral</strong> <strong>MIS</strong> Spinal <strong>System</strong>The <strong>Coral</strong> <strong>MIS</strong> Spinal <strong>System</strong> extends theapplication of the <strong>Coral</strong> Spinal <strong>System</strong> to minimallyinvasive surgical procedures of the lumbar spine.Utilizing the experience obtained from the proven<strong>Coral</strong> Spinal <strong>System</strong>, <strong>Coral</strong> <strong>MIS</strong> is designed to beeasy to use while addressing advanced indicationswith a less invasive approach. The simplicity of the<strong>Coral</strong> <strong>MIS</strong> system reduces the number of requiredsteps while utilizing all the advantages of thecomprehensive <strong>Coral</strong> Spinal <strong>System</strong>.One Step Screw Extension AttachmentScrew Extensions attach to screw heads in one step,simplyfing the surgical process and reducing OR time.Multiple Rod Inserter OptionsSurgeons can select a rod inserter to fit theirspecific needs.Threaded Rod ReductionRod reduction is simple and controlled by attachingthreaded drive nut to Screw Extension.One Step Screw ExtensionAttachmentMultiple Rod InserterOptionsThreaded Rod ReductionMulti-Level Capabilities


<strong>Integra</strong> <strong>Coral</strong> <strong>MIS</strong> Spinal <strong>System</strong><strong>Coral</strong> Cannulated Polyaxial Screws45° of screw head angulationPre-Bent RodsDiameterLengths*DiameterLengths5.5mm6.5mm7.5mm8.5mm30mm – 50mm30mm – 55mm30mm – 55mm35mm – 50mm5.5mm30mm – 80mm* 4.75mm and 9.5mm screws available by special requestStraight RodsDiameter5.5mm5.5mmLengths200mm400mmRod Length Indicator allows accuratemeasurement above the skin lineSimple rod insertionSimple Compression/Distraction CapabilitiesFor more information or to place an order, please contact:<strong>Integra</strong> n 1153 Medina Rd. Medina, OH 44256866-942-8698 USA n 877-558-6227 faxintegralife.com<strong>Coral</strong> <strong>MIS</strong>, <strong>Integra</strong>, and the <strong>Integra</strong> logo are trademarks of <strong>Integra</strong> <strong>LifeSciences</strong> Corporation.©2011 <strong>Integra</strong> <strong>LifeSciences</strong> Corporation. All rights reserved. Printed in the USA SS-28-001 Rev A

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!