4System Configuration Example1. Connecting between <strong>FA</strong>-M3 ControllersThe F3LP02-0N can be used to configure a system inwhich communication speed can be as high as 1.25Mbps.<strong>FA</strong>-M3F3LP02-0N<strong>FA</strong> <strong>Link</strong> H module<strong>FA</strong> <strong>Link</strong> H modules(1.25 Mbps max., 1 km max., 32 stations)<strong>FA</strong>-M3 <strong>FA</strong>-M3 <strong>FA</strong>-M32. Connecting between <strong>FA</strong>-M3 Controllers, <strong>FA</strong>500 andµ<strong>FA</strong>20<strong>FA</strong>-M3F3LP02-0N<strong>FA</strong> <strong>Link</strong> H Module<strong>FA</strong>-M3F3LP02-0N <strong>FA</strong> <strong>Link</strong> H ModuleLP01-0N<strong>FA</strong> <strong>Link</strong> Module<strong>FA</strong>500for <strong>FA</strong>500µ<strong>FA</strong>20<strong>FA</strong> link 250 kbps (500 m max., 32 stations)- Set the transmission speed of the <strong>FA</strong> <strong>Link</strong> H moduleto 250 kbps.External Connection DiagramTerminatingresistor<strong>FA</strong> link HmoduleABSGSHIELD<strong>FA</strong> link HmoduleABSGSHIELDMaximum total cable length: S m<strong>FA</strong> link HmoduleABSGSHIELDTerminatingresistor1. The maximum total cable length (S) varies dependingon the transmission speed used.2. The SHIELD terminal of this module is internallyconnected to the FG terminal of the <strong>FA</strong>-M3 powersupply module.3. This module has a built-in terminator. Whenconfiguring the module at the end of the cable, set theterminator switch to ON.CablesUse two-pair (4-wire) shielded cable (impedance 100 Ω )when connecting <strong>FA</strong> <strong>Link</strong> H modules.Recommended cables: KM80-□□□/KM81-□□□ (tobe purchased separately).* For details on KM80-□□□and KM81-□□□, see“<strong>FA</strong>-M3 YHLS Master Module, YHLS Slave Units andYHLS Communication Cables (for implementinghigh-speed remote I/O) (GS 34M06H46-03E).Operating Environment- The table below lists the CPU modules that can beused with this module.CPU ModuleF3SP21, F3SP25 and F3SP35F3SP05/ 08, F3SP22, F3SP28, F3SP38,F3SP53/58/59, F3SP66/67,F3SP71-4S, F3SP76-7SStyle No. and ROM Rev.S1 Rev. 8 or laterNote: For the revision number of a CPU module, see the revision numberlabel on the side panel.- The following table summarizes the requirements forthe Ladder Diagram Support Program M3, which canbe used to set up the communications conditions ofthis module. All versions of the Ladder ProgrammingTool WideField3, WideField2 and WideField can beused with this module.Ladder Diagram SupportRevisionProgram M3SF510-E3Rev. 1.08 or laterModel and Suffix CodesModelSuffixCodeStyleCodeOptionCodeF3LP02 -0N . . . . . . . . . .External Dimensions—Description32 stations max.125 k, 250 k, 625 k or 1.25 Mbps1 km, 500 m, 250 m or 100 m83.2 12.128.92Unit:mm100FB0251.VSDAll Rights Reserved. Copyright © 2012, <strong>Yokogawa</strong> Electric Corporation GS 34M06H43-01E Jun., 2012-00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!