13.07.2015 Views

FA Link H Modules FA-bus Modules - Yokogawa

FA Link H Modules FA-bus Modules - Yokogawa

FA Link H Modules FA-bus Modules - Yokogawa

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

8System Configuration Example• Star Configuration<strong>FA</strong>-M3 Unit No. 0Main unit<strong>FA</strong>-M3 <strong>FA</strong>-M3 <strong>FA</strong>-M3Unit No. 1Unit No. 2Unit No. 3Operating EnvironmentThere is no restriction on the type of CPU modules thatcan be used with this module.Model and Suffix CodesModelSuffixCodeStyleCodeOptionCodeF3LR01 -0N . . . . . . . . . .DescriptionMaximum total distance:200 mMaximum distancebetween stations: 200 mSub-units*F3LR01-0N Fiber-optic <strong>FA</strong>-<strong>bus</strong> modulefor <strong>FA</strong>-M3External DimensionsUnit: mm• Daisy-chain + Star Configuration<strong>FA</strong>-M3 Unit No. 0Main unit<strong>FA</strong>-M3 <strong>FA</strong>-M3 <strong>FA</strong>500Unit No. 1Unit No. 2Unit No. 3Sub-units*<strong>FA</strong>-M3<strong>FA</strong>500Unit No. 5*: Maximum number of sub-units: 7Unit No. 4F3LR01-0N Fiber-optic <strong>FA</strong>-<strong>bus</strong> modulefor <strong>FA</strong>-M3LR20-0N Fiber-optic <strong>FA</strong>-<strong>bus</strong> modulefor <strong>FA</strong>500Restrictions on System ConfigurationItemMaximum total distanceNumber of connectablesub-unitsNumber of fiber-optic <strong>FA</strong>-<strong>bus</strong>modules installable in a mainunitNumber of fiber-optic <strong>FA</strong>-<strong>bus</strong>modules installable in asub-unit<strong>Modules</strong> installable in asub-unit200 m7 max.Description7 max.(no restrictions on the installationlocation)1(no restrictions on the installationlocation)All I/O modules, and special modulesexcept F3LP , F3LE01, F3LX0and F3NX01 modules.Optional AccessoriesPrepare fiber-optic cables satisfying the requirementslisted below when connecting Fiber-optic <strong>FA</strong>-<strong>bus</strong>modules for extension. See Fiber-optic Cables(GS 34M06C92-01E) for details on fiber-optic cables.• Specifications for Fiber-optic Cable Cores<strong>Yokogawa</strong> CableModel NumberKM60KM60,KM61,KM62,KM65Fiber-optic CableModel No. (Size)DK-HPF200/230 2×CCV-HC-20/07Fiber-optic CabletypeSI type※1SI type※1VendorSWCC Showa Sumitomo ElectricCable SystemIndustriesCore diameter200±5μmClad diameter 230 + 0-10 μmTransmission loss7.0dB/km Max.7dB/km Max.(λ=0.85μm,Ta=25℃) (λ=0.81μm,Ta=25℃)※1:Step-index optical fiber• Specifications for Fiber-optic Cable Connectors<strong>Yokogawa</strong> CableModel NumberOptical connectorsModel No.VendorSpecificationsKM60KF-07SWCC ShowaCableSystemsBi-directional,lever lockbonding,polishedKM65CF-2011CF-2071SumitomoElectricIndustriesBi-directional,lever lock,crimping, cutKM60,KM61KM62,KM67CF-2001HCF-2071HSumitomoElectricIndustriesBi-directional,lever lockbonding,polishedAll Rights Reserved. Copyright © 2012, <strong>Yokogawa</strong> Electric Corporation GS 34M06H43-01E Jun., 2012-00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!