13.07.2015 Views

FA Link H Modules FA-bus Modules - Yokogawa

FA Link H Modules FA-bus Modules - Yokogawa

FA Link H Modules FA-bus Modules - Yokogawa

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

6Configuration ExampleExternal Dimensions• Daisy-chain configurationUnit: mmF3LP12-0NFiber-optic <strong>FA</strong> <strong>Link</strong> H moduleFiber-optic <strong>FA</strong> <strong>Link</strong> H1. The maximum distance between stations is 1 km andthe maximum total distance is 10 km.2. The attached blank cover must be placed on anyunused port of the terminating station.Operating Environment- There is no restriction on the type of CPU modulesthat can be used with this module.CPU ModuleStyle No. and ROM Rev.F3SP21, F3SP25 and F3SP35S1 Rev. 8 or laterF3SP05, F3SP 08, F3SP22, F3SP28,F3SP38, F3SP53/58/59,F3SP66/67,—F3SP71-4S, F3SP76-7SNote: For the revision number of a CPU module, see the revision numberlabel on the side panel.- The following table summarizes the requirements forthe Ladder Diagram Support Program M3, which canbe used to set up the communications conditions ofthis module. All versions of the Ladder ProgrammingTool WideField3, WideField2 and WideField can beused with this module.Ladder Diagram SupportRevisionProgram M3SF510-E3Rev. 1.08 or laterModel and Suffix CodesModelSuffixCodeStyleCodeOptionCodeF3LP12 -0N . . . . . . . . . .Description32 stations max.Maximum total distance: 10 kmMaximum distance betweenstations: 1km1.25MbpsOptional AccessoriesThe customer should prepare fiber-optic cablessatisfying the requirements listed below when connectingbetween Fiber-optic <strong>FA</strong> <strong>Link</strong> H modules. See Fiber-opticCables (GS34M06C92-01E) for details on fiber-opticcables.• Specifications for Fiber-optic Cable Cores<strong>Yokogawa</strong> CableModel NumberKM60KM60,KM61,KM62,KM65Fiber-optic CableModel No.(Size)DK-HPF200/230 2×CCV-HC-20/07Fiber-optic CabletypeSI type※1SI type※1VendorSWCC Showa Sumitomo ElectricCable SystemIndustriesCore diameter200±5μmClad diameter 230 + 0-10 μmTransmission loss7.0dB/km Max.7dB/km Max.(λ=0.85μm,Ta=25℃) (λ=0.81μm,Ta=25℃)※1:Step-index optical fiber• Specifications for Fiber-optic CableConnectors<strong>Yokogawa</strong> CableModel NumberOptical connectorsModel No.VendorSpecificationsKM60KF-07SWCC ShowaCableSystemsBi-directional,lever lockbonding,polishedKM65CF-2011CF-2071SumitomoElectricIndustriesBi-directional,lever lock,crimping, cutKM60,KM61KM62CF-2001HCF-2071HSumitomoElectricIndustriesBi-directional,lever lockbonding,polishedAll Rights Reserved. Copyright © 2012, <strong>Yokogawa</strong> Electric Corporation GS 34M06H43-01E Jun., 2012-00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!