13.07.2015 Views

Electricity meters for modular enclosures and DIN rail

Electricity meters for modular enclosures and DIN rail

Electricity meters for modular enclosures and DIN rail

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

DELTAsingleTechnical dataSingle phase meter, direct connection up to 80AType FBxVoltage (V) Nominal voltage AC 1 x 220 - 240Voltage range-20% to +15% of norminal voltageCurrent (A) I min0.5I tr1.0I ref(I b) 10I nImax 80I st25 mAGeneral data Frequency (Hz) 50/60Frequency range ± 5%Accuracy Class B (Cl. 1)Power consumption current circuits at 230 VAC <strong>and</strong> I ref0.02 VA, 0.02 WPower consumption voltage curcuits1.3 VA, 1.3 WSt<strong>and</strong>ards MID approval according to EN 50470-1, EN 50470-3International approlval according to IEC 62052-11, IEC 62053-21Memory back-upClock back-upEEpromSuper Cap. typically 168 hours back-up at +20°C, min 48 hours over operating temperature rangeClock accuracy IEC 62052-11, IEC 62054-21Temperature range (°C) Operating -40 to +55Storage -40 to +70Trans<strong>for</strong>mer ratio Voltage trans<strong>for</strong>mer ratio N/ACurrent trans<strong>for</strong>mer ratioN/AMax trans<strong>for</strong>mer ratioN/AEnclosure material Upper PolycarbonateLowerGlassfibre rein<strong>for</strong>ced polycarbonateEnvironment Mechanical environment M1Electromagnetical environmentE2Resistance to heat <strong>and</strong> fire According to IEC 60695-2-10, IEC 60695-2-11,Terminal 960°C, Cover 650°CHumidity75% yearly average, 95% on 30 days/yearConnection area main terminals Current terminals 1 x mm 2 4 - 25Voltage terminals 1 x mm 2N/AProtection against penetration of dust According to IEC 60529 IP 20 on terminal block without protective enclosure *<strong>and</strong> water )Pulse output Connection area, main terminals, - 1 x mm 2 0 - 2.5External pulse voltage- Voltage (V) DC 5 - 40 (Transistor output)- Voltage (V) AC/DC N/AMax. current (mA) 100Pulse length (ms) 100 (± 2.5)Pulse frequency (imp/kWh) 100St<strong>and</strong>ardIEC 62053-1 (SO)LED Pulse frequency (imp/kWh) 1000Pulse length (ms) 40DisplayLCD with 6 digits, height 6 mmElectromagnetic compability (EMC) Impuls voltage test (kV) 6, 1.2 / 50µs (IEC 60060-1, HD 588.1 S1)Fast transient burst test (kV) 4 (IEC 61000-4-4)Radio frequency immunity 80 MHz - 2 GHz at 10 V/m (IEC 61000-4-3)Electrostatic discharge (ESD) (kV) 15 (IEC 61000-4-2)Tariff inputs (optional) Max. voltage (V) AC N/AMax. wire size (mm 2 )N/AInput voltage range (V) ACN/ATerminal wire area (mm 2 ) M-Bus N/ALonWorks FTT-10AN/ADimensions Width (mm) 72Height (mm) 95Depth (mm) 63.6<strong>DIN</strong> modules 4*) To comply with the protection requirements the meter must be mountedin a class IP 51 enclosure or better, acc to IEC 60529.2CMC480022C0003| <strong>Electricity</strong> <strong>meters</strong> 19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!