13.07.2015 Views

Triton T60si - Faucets, Showers, Bathroom, Kitchen, More.

Triton T60si - Faucets, Showers, Bathroom, Kitchen, More.

Triton T60si - Faucets, Showers, Bathroom, Kitchen, More.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>T60si</strong>IsolatingstopvalveMainswatersupplyMains electric supply (via double pole switch)ShowerunitDoublepoleisolatingswitchSeparate permanentlyconnected supplyfrom consumer unitFig.4Diagrammatic view (not to scale)WATER REQUIREMENTSThe installation must be in accordance with WaterRegulations/Byelaws.To ensure activation of the heating elements, theshower must be connected to a mains watersupply with a minimum running pressure of100 kPa (1.0 bar) at a minimum flow rate of eightlitres per minute and a maximum static pressureof 1,000 kPa (10 bar).NOTE: If the stated flow rates are not available, itmay not be possible to achieve optimumperformance from the unit throughout the year.During periods of high ambient temperatures itmay be necessary to select a low power setting toachieve your preferred shower temperature.The water supply can be taken from a cold waterstorage cistern provided there is a minimum headof ten metres above the sprayhead. It must be anindependent supply to the shower only.If it is intended to operate the shower at pressuresabove the maximum or below the minimumstated, contact Customer Service for advice.Fig.4 shows a typical system layout.Do not use jointing compounds on any pipefittings for the installation.SITING OF THE SHOWERWARNING: The shower must not bepositioned where it will be subjected tofreezing conditions.FOR EASE OF SERVICING, THE UNIT MUSTALWAYS BE MOUNTED ON THE SURFACE OFTILED WALLS. NEVER TILE UP TO THE UNIT.Refer to figure 5 for correct siting of shower.Position the unit where it will NOT be in directcontact with water from the sprayhead. Positionthe shower unit vertically.Allow sufficient room between the ceiling and theshower to access the cover top screws.NOTE: Water regulations require the sprayhead be‘constrained by a fixed or sliding attachment sothat it can only discharge water at a point not lessthan 25mm above the spill-over level of therelevant bath, shower tray or other fixedappliance’. The use of the supplied retaining ringwill in most cases meet this requirement, but ifthe sprayhead can be placed within a bath, basin6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!