g. Trip status of the following:1) Network off command status2) Undercurrent3) Overcurrenth. Last fault 1i. Last fault 2j. Last fault 3k. Last fault 4l. Unit IDm. Model coden. Motor run hours2. The equipment shall provide the following readable/writable setpoints:a. Low voltage trip pointb. High voltage trip pointc. Current multiplierd. Overcurrent trip pointe. Undercurrent trip pointf. Trip class setpointg. Restart delay 1 setpointh. Restart delay 2 setpointi. Restart delay 3 setpointj. Number of restarts after an undercurrent fault (#RU) setpointk. Number of restarts after a fault (#RO) setpointl. Undercurrent trip delay setpointm. Modbus address setpointn. Network status setpoint to enable the following features:1) Network watchdog2) Network program disable3) Front panel locko. Time units setpointp. Linear overcurrent trip delayq. Command line to respond to the following commands:1) Network program enable2) Network program disable3) Clear run hours4) Clear last fault5) Enable network watchdog6) Disable network watchdog7) Start the motor8) Stop the motorD. Capabilities and Features1. Inputsa. The equipment shall require a single-phase input voltage of 100-240VAC.b. The equipment shall require a single-phase 50/60 Hz input voltage.c. The equipment shall provide a connection to an optional external remote reset switch.d. The equipment shall require no external CT’s for motors with full load current ratings between 2 and 90 amps.e. The equipment shall require external CT’s for motors with full load current ratings greater than 90 amps.f. The equipment shall accept full load current of 2-800 amps.2. Outputsa. The equipment shall include one Form C (S<strong>PD</strong>T) output relay. Contacts pilot duty rated 480VA@240VAC.Contacts general purpose rated 10A@240VAC.3. Functional Specificationsa. The equipment shall include the following front panel setpoint ranges:1) an adjustable low voltage (LV) setpoint range of 85-262VAC2) an adjustable high voltage (HV) setpoint range of 86-264VAC3) an adjustable trip class (TC) setpoint range of 5, J5, 10, J10, 15, J15, 20, J20, 30, J30, Lln4) an adjustable rapid-cycle timer 1 (RD1) of 0, 2-500 seconds5) an adjustable motor cool-down timer (RD2) of 2-500 minutes6) an adjustable undercurrent restart delay timer (RD3) of 2-500 minutes7) an adjustable number of restarts after undercurrent (#RU) setpoint range of 0-4, A (automatic)8) an adjustable device communication address (ADDR) setpoint range of A01-A999) an adjustable number of restarts after OC faults (#RO) setpoint range of 0-4, A (automatic)10) an adjustable undercurrent trip delay (UCTD) setpoint range of 2-60 seconds11) an adjustable linear overcurrent trip delay (OPT1) setpoint range 2-60 seconds12) an adjustable setting to define RD2 and RD3 in seconds or minutes (OPT2) of 1-313) an adjustable multiplier (MULT) setpoint range of 1-10, 100, 150, 200, 300, 400, 500, 600, 700, 80014) an adjustable overcurrent (OC) setpoint range of (20-100A) ÷ MULT or 80-120% of CT PrimaryES-77C_A1 4/28/2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!