13.07.2015 Views

Optical Remote Control Compatible, High-Accuracy Digital Indicator

Optical Remote Control Compatible, High-Accuracy Digital Indicator

Optical Remote Control Compatible, High-Accuracy Digital Indicator

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

AFunctionality Meets the Needs of Diverse Measurement• Tolerance judgmentOK, +NG or -NG is shown for a measurement based on theupper/lower limit values currently set. If an out-of-tolerance valueis detected, the backlight turns red to help with workpiece sortingoperations.• Analog bar displayThe analog bar display makes it easy to quickly find maximum/minimum readings.Seven ranges from ±.0004" to ±3.15" (±0.01mm to ±80mm) canbe selected to suit the task at hand.• Large charactersThe 7-digit digital display uses large characters for ease of reading.• Maximum/minimum value based measurementA comparison measurement can be made on the basis of thedetected maximum or minimum values that has been zero-set. Forexample, this method is convenient for measurement in which themaximum value at a workpiece peak is zero-set and other values aremeasured in comparison with this vaue.• <strong>Remote</strong> operationsThe indicator can be operated remotely by using the remotecontroller, or a personal computer via the built-in RS232C interface.• Two ways of measuringA measurement can be made relative to zero (Incremental) or relativeto an arbitrary value entered into the display (Absolute), whichever ismost convenienent.• Function lockThe setting conditions can be locked to prevent them beingaccidentally changed during use.• Resolution switchingThe resolution can be selected to be .00002" (0.0005mm) (0.5µm)or .00005" (0.001mm) (1µm).• Measuring maximum value, minimum value andrunoutMaximum value/minimum value measurementMaximum or minimum values are automatically held and displayed.Difference/RunoutmeasurementDifference (or Total Runout, on a circularworkpiece) between a maximum and aminimum value is held and displayed. Themaximum/minimum values are stored inmemory and can also be displayed.Example: <strong>Indicator</strong> travel from points A to DDifference (or Total Runout) is displayed as A. Dimensions B(maximum value) and C (minimum value) can be recalled frommemory with a simple key sequence.Point B• Direction switchingThe counting direction can be reversed.• Selectable output modeThis indicator not only supports simplerecording of measurement data usingthe well-established Digimatic output,but also enables integration into ameasurement system through advancedcontrol via the RS-232C interface.• <strong>Remote</strong> spindle liftingThe spindle can be lifted up to 1.20"(30mm) without touching the indicatorbody by using the dedicated spindle liftingcable (optional accessory). The spindlecan be lifted over the full stroke by usingthe lifting knob (optional accessory) thatattaches to the top of the spindle.Lifting knobPoint APoint DBCPoint C

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!