13.07.2015 Views

Wind Energy Feasibility Study - Town Of Orleans

Wind Energy Feasibility Study - Town Of Orleans

Wind Energy Feasibility Study - Town Of Orleans

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Wind</strong> <strong>Energy</strong> Facility Economic Analysis<strong>Town</strong> of <strong>Orleans</strong>, MAthrough the existing water treatment plant is assumed, as it would require the least amount oftemporary improvements. The amount of cut was estimated to be 2,350 cubic yards, with a netimport of 1,100 cubic yards for filling low lying areas to create slopes passable by crane andmaterials delivery vehicles. The temporary access roads would be removed at the completion ofthe project so that the existing water main will be accessible.4.3 Engineering and Other Related CostsThe cost estimate includes “soft” costs for the required studies, permitting, design and otherrelated efforts in addition to capital costs for the procurement and installation of the turbine;construction of foundation, electrical interconnection, and erection of the turbine,commissioning, and testing costs. Legal costs, public relations, and a budge for contingencyitems were not included the cost estimate, but should be considered as with any capitalimprovement project. The total cost for developing a single 600 kW wind turbine is estimated tobe on the order of $2,300,000. Table 4-1 summarizes the estimated cost of development of asingle 600 kW wind turbine.20

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!