Wind Energy Feasibility Study - Town Of Orleans
Wind Energy Feasibility Study - Town Of Orleans
Wind Energy Feasibility Study - Town Of Orleans
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Manufacturer and typePitch rate, Deg./sec.Pitch mechanism, electric/hydraulicPressureCylinder force ,kNFeathering system (including backup)Parker or Equivalent4.6 deg/secHydraulically225 bar250 kNHydraulicallyT600-48 TURBOWINDS7 TowerType and Material ST 42Height, m50 mDiameter and Thickness at top, cm209.4 cm - 1.2 cmDiameter and Thickness at base, cm314.0 cm - 2.5 cmTower Layoutcylindrical – taperedFirst bending frequency , Hz0.9 HzAccess to nacelleinside towerCorrosion prevention3 coat paintingWithstanding seismic loads0.35 g8 Power Generation SystemGenerator:ManufacturerABB / SiemensType and Model number M2CG 400 XL 4/6Rating, kW120/ 600 kWRated current123/566 AmpSlip 0.7 % / 0.9 %Power Factor ( 100%-75%-50%-25%) 0.89 - 0.88 - 0.85 - 0.68Voltage, V690 VACFrequency, Hz60HzSpeed, rpm1200/1800 rpmInsulationclass FMaximum working temperature, C45 degrees ambient tempEfficiency (100%-75%-50%-25%) 96.9 % - 96.7 % - 96.2 % -94.1% respectively<strong>Wind</strong>ing protection type IP 55Safety device3 PTC’s per generatordBA at 1 meter distance< 85 dBAConnection to grid, direct/softsoft startedElectricals:Reactive power compensation &APFCT600-48 TURBOWINDS50/150 kVar ,& 175KVAR,6