13.07.2015 Views

Known Issues for S8400 - Avaya Support

Known Issues for S8400 - Avaya Support

Known Issues for S8400 - Avaya Support

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ID and Keywords Symptom:022021sMaintenance, Alarm,Media Gateway,H.248 IP021967sEndpoint / Appliance /Telephone, ISDN,H.323 IP, Trunk,Media Gateway,Blocked/DroppedCall, H.248 IP021923sReliability,Maintenance, LSP(Local SurvivableProcessor), Upgrade,Registration, Endpoint/ Appliance /Telephone021533hNetworking,Maintenance, MediaGateway, FileTransfer, H.248 IP021530sAdministration,Reliability, Endpoint /Appliance /Telephone, LSP(Local SurvivableProcessor), Display021314sCall Center, ServiceObserving, Button,Talkpath, Endpoint /Appliance /Telephone,Blocked/Dropped Call021127hNetworking, CallCenter, Trunk, MediaGateway, H.248 IP020442sAdministrationIF:- An alarm LED indicates a problem with a G700 Media Gateway, and- You verify that no such problem condition exists…THEN:…The LED nevertheless remains on.IF:- A Remote Access call comes into a server over an ISDN trunk ratherthan an H.323 IP trunk, and- The call goes back out of the server to an endpoint connected via a COtrunk in a G700 media gateway…THEN:…The connection to the endpoint fails.IF:- You upgrade the primary controller…THEN:…The endpoints unregister from the primary controller and canpotentially register with a local survivable processor (LSP).IF:- An Embedded Web image has been downloaded to the P330 in a G700Media Gateway…THEN:…The version in bank A (where that image resides) appears as 0.0.0.IF:- An LSP (Local Survivable Processor) is in a time zone different fromthat of its primary server, and- That LSP takes over call processing…THEN:…The time displayed on the endpoints is inaccurate.IF:- A local service observer is in listen/talk mode, and- The service observer presses the VOA (VDN of Origin Announcement)button…THEN:…The observer's talkpath might be lost. When this occurs, the ServiceObserving button continues to flash as if it is still in listen/talk mode.IF:- A call uses an analog trunk on a G700 Media Gateway, and- The caller hangs up…THEN:…The trunk might be idled be<strong>for</strong>e the network returns a disconnectconfirmation from the other end of the call. If the trunk is carrying a highcall rate, as in a call center, there is risk of re-using that trunk be<strong>for</strong>e it isactually available.IF:- You want to update one or more items in a server's configuration…THEN:…You must go through the entire list of items in the Configure Serverweb pages to find the desired item to change.WorkaroundIf the LED remains on even after you verify that noalarms are present, check that the LED panelboard is correctly seated.Administer Remote Access calling not to use ISDNtrunks.Shut down all LSPs be<strong>for</strong>e upgrading the primarycontroller.To see the version number of the Embedded Webimage, use the 'dir' command. Look at the versionnumber <strong>for</strong> the EW_Archive.Administer the LSP to be in the same time zoneand have the same time as the primary server. Inthe web pages on the LSP, set the time zone andtime accurately.To recover the talkpath, the service observer cantoggle the Service Observing button to Listen Onlyand then back to Listen/Talk.Increase the Incoming Glare Guard and OutgoingGlare Guard timers on the central office trunkgroup <strong>for</strong>m.Go through the list.© 25 June 2007 <strong>Avaya</strong><strong>Avaya</strong> Communication Manager, Release 4.0<strong>Known</strong> <strong>Issues</strong> and Workarounds <strong>for</strong> the <strong>S8400</strong> ServerPage 6 of 6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!