13.07.2015 Views

SITRANS F flowmeters - Industria de Siemens

SITRANS F flowmeters - Industria de Siemens

SITRANS F flowmeters - Industria de Siemens

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>SITRANS</strong> F <strong>flowmeters</strong><strong>SITRANS</strong> F MSystem information <strong>SITRANS</strong> F Melectromagnetic <strong>flowmeters</strong>© <strong>Siemens</strong> AG 20094■ Technical specificationsFlowmeter Calibration and traceabilityTo ensure continuous accurate measurement, <strong>flowmeters</strong> mustbe calibrated. All measuring instrumentation, used in the calibrationof the <strong>flowmeters</strong>, has either been calibrated by a UKAS orDANAK accedited laboratory or has been calibrated againstcertified master sensors. This provi<strong>de</strong>s an unbroken chain ofmeasurement-traceability to national standards.<strong>Siemens</strong> Flow Instruments can provi<strong>de</strong> accredited calibration inthe flow range from 0.0001 m 3 /h to 4350 m 3 /h.The accreditation bodies DANAK and UKAS have signed theILAC MRA agreement (International Laboratory AccreditationCorporation - Mutual Recognition Arrangement). Therefore theaccreditation ensures international traceability and recognitionof the test results in 39 countries world wi<strong>de</strong>, including the US(NIST traceability).A calibration certificate is shipped with every sensor and calibrationdata are stored in the SENSORPROM memory unit.Flowmeter uncertaintyReference conditionsReference conditions (ISO 9104 and DIN EN 29104)Temperature medium20 °C ± 5K (68°F ± 9°F)Temperature ambient20 °C ± 5K (68°F ± 9°F)Supply voltage U n ± 1%Warming-up time30 minutesIncorporation in conductive pipesection• Inlet section 10 x DN (DN ≤ 1200/48”)5 x DN (DN > 1200/48“)• Outlet section 5 x DN (DN ≤ 1200/48”)3 x DN (DN > 1200/48“)Flow conditionsFully <strong>de</strong>veloped flow profileAdditions in the event of <strong>de</strong>viations from reference conditionsCurrent outputAs pulse otput (± 0.1% of actualflow + 0.05% FSO)Effect of ambient temperature• Display / frequency / pulse output < ± 0.003%/K act.• Current output< ± 0.005%/K act.Effect of supply voltage< 0.005% of measuring value on1% changeRepeatability± 0.1% of actual flow forv ≥ 0.5 m/s (1.5 ft/s) and conductivity> 10 μS/cmCertificates• EN 10204 2.1Certificate of conformity, statingthat the <strong>de</strong>livered parts are ma<strong>de</strong>of the material quality that wasor<strong>de</strong>red• EN 10204 2.2Test report certificate, a nonbatch specific material analysis ofthe or<strong>de</strong>red material• EN 10204 3.1Material analysis certificate, abatch specific analysis of thematerial issued by an in<strong>de</strong>pen<strong>de</strong>ntinspectorMAG 5000 and MAG 6000/6000I with MAG 1100 (PFA)/MAG 1100 F (PFA)MAG 6000 or MAG 6000 I used with MAG 3100, MAG 1100 (Ceramic) orMAG 5100 W4/20 <strong>Siemens</strong> FI 01 · 2009March 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!