3. Initial operation3.1 Getting the system ready for operationBefore greasy waste water is filled into the system➤ it must be cleaned completely (including inlets and outlets);solids and coarse materials must be removed.➤ The cleaned system must be filled with cold water up tothe overflow (this is not relevant, of course, if the tankshave been checked for airtightness and the water hasnot been pumped out).3.2 Instruction / handoverInitial operation and instruction are generally carried out by afitter, but they can also be carried out by someone sent by<strong>KESSEL</strong> on request and for an extra charge.1. The following persons should be present for the handover:➤ Person authorised to perform the acceptance on behalfof the building owner➤ Sanitary fitterIn addition, we recommend the participation of➤ Operating staff➤ Disposal company2. Preparation of instruction and handover:➤ Sanitary installations must have been completed➤ The system must be ready to be filled with water (seesection 3.1)3. Instruction:➤ Check the system for airtightness, transport and installationdamage and check the pipe connections➤ Information about emptying (extraction)➤ Practical demonstration of the operating possibilities4. Handover of installation and operating instructionsOnce the instruction has been completed, the system mustbe made ready for operation again.3.3 Handover certificate(see page 12)3.4 DisposalWith version G, the grease must be skimmed off daily.Emptying intervals:Grease separator systems must be emptied and cleanedonce a week.Caution: Correct function can only be guaranteed if thesystem content is disposed of in good time.With version D, initial disposal must be carried out within 2-3 weeks.Emptying intervals:According to DIN 4040, grease separators must be emptieddepending on quantities every 14 days, but at least onceper month, whereby the grease layer capacity of the systemis 160 mm in compliance with the standard.Caution: Correct function can only be guaranteed if thesystem content is disposed of in good time.A disposal contract should therefore be concluded with aprofessional company. If possible, disposal work should becarried out outside business hours. When the separatortank is opened, odour pollution must be expected.Performing the disposal➤ Loosen the clamping ring and take the cover off➤ Clean the tank walls, dispose of residue grease➤ Fill tanks with water➤ Clean and check cover seal (renew if necessary)➤ Close the cover with the clamping ring5. Drawing up the handover certificate.Accessories can usually be retrofitted. Please address anyqueries you may have to our sales department4. Accessories22

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!