Ro/Ro Spaces - Cargo Ships• The drainage system shall be sized to remove no less than 125% <strong>of</strong>the combined capacity <strong>of</strong> both the w<strong>at</strong>er spraying system pumps andthe required number <strong>of</strong> fire hose nozzles• The drainage system valves shall be operable from outside theprotected space <strong>at</strong> a position in the vicinity <strong>of</strong> the extinguishingsystem controls.• Bilge wells shall be <strong>of</strong> sufficient holding capacity and shall bearranged <strong>at</strong> the side shell <strong>of</strong> the ship <strong>at</strong> a distance from each other <strong>of</strong>not more than 40 m in each w<strong>at</strong>ertight compartment.• If this is not possible the adverse effect upon stability <strong>of</strong> the addedweight and free surface <strong>of</strong> w<strong>at</strong>er shall be taken into account to theextent deemed necessary by the Administr<strong>at</strong>ionM.Ventura <strong>SOLAS</strong> - Fire Protection 95Fire Protection in Ro/Ro Spaces• Portable extinguishers shall be provided <strong>at</strong> each deck level in eachhold or compartment where vehicles are carried, spaced not more than20 m apart on both sides <strong>of</strong> the space.• At least one portable fire-extinguisher shall be loc<strong>at</strong>ed <strong>at</strong> each accessto such a cargo space.• Additionally, vehicle, Ro-Ro and special c<strong>at</strong>egory spaces intended forthe carriage <strong>of</strong> motor vehicles with fuel in their tanks for their ownpropulsion shall be provided with:– At least 3 w<strong>at</strong>er fog applic<strong>at</strong>ors– 1 portable foam applic<strong>at</strong>or unit, provided th<strong>at</strong> <strong>at</strong> least two suchunits are available in the ship for use in such ro-ro spaces.Ventil<strong>at</strong>ion System• Enclosed garage spaces shall have ventil<strong>at</strong>ion system guaranteeing 6renov./hour, based on the empty volumeM.Ventura <strong>SOLAS</strong> - Fire Protection 9648

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!