<strong>ODU</strong> <strong>MINI</strong>-<strong>SNAP®</strong> Series FTechnical InformationOperating Voltage acc. to SAE AS 13441-Method 3001.1The values acc. to SAE AS 13441-method 3001.1 complywith MIL-STD 1344-method 3001.The chart values results are acc. to IEC 60512-2; Test 4. Theinserts have been tested in mated condition and the testvoltage was applied to the pin insert.75 % of the measured break-down voltage is the basic forthe further calculation. 1⁄3 of this value is the correspondingoperating voltage.All tests were performed at standard environment conditions(room temperature) and can be applied up to analtitude of 2,000 m.For any deviations one has to consider the reductionfactor acc. to the relevant standards.CautionElectrical appliances: for various applications the safetyrequirements regarding the operating voltage is evenmore severe!The relevant datas in such cases for the operating voltageare the creepage and clearance distances.For any advise how to choose the proper connectorplease consult us and indicate the safty standard whichyour product has to meet.Test voltage: Break-down voltage × 0.75Operating voltage: Break-down voltage × 0.75 × 0.33Technical InformationPage 76www.odu.de