<strong>ODU</strong> <strong>MINI</strong>-<strong>SNAP®</strong> Series FTechnical InformationAutoclaving of the <strong>ODU</strong> <strong>MINI</strong>-<strong>SNAP®</strong>If required <strong>ODU</strong> can deliver <strong>MINI</strong>-SNAP connectors for the following sterilization process:Steam-sterilization with pre-vacuum or gravitation-process. Connectors were tested withautoklave equipment with reference to DIN EN 13060 at 134° C and 500 cycles.Sterilization curve3,000pressure inmbar abs.2,0001,013Time0Ventilation Increase of pressure SterilizationSterilization cycleDryingFor other sterilization-processes please contact our technical support team.Technical Information1. Pre-vacuumPressure increasePressure decrease2. Pre-vacuumPressure increaseTemperature increasein transitionInfluence5 min. at 134° C15 min. at 121° CPressure decreaseAfter-vacuumDrying timeVentilationPage 783000Druck inmbar abs.www.odu.de