RE-Y(St)Y-fl<br />
RE-2Y(St)Y-fl<br />
RE-2X(St)Y-fl<br />
EN 50288-7<br />
Multi-Pair, General Screened, Instrumentation Cables300 V - 500 V<br />
KLAS KABLO RE-Y(St)Y-fl<br />
APPLICATION<br />
These cables are generally employed in instrumentation and control systems, analog and digital signal transmission of chemical and petrochemical industrial premises,<br />
power plants, natural gas and petroleum industries, etc. Direct connection is not permitted under ambient with a low impedance sources. Cables with blue sheaths are<br />
suitable for security system applications. Furthermore, these cables can directly be buried in the soil. They are suitable in dry and wet indoor and outdoor installations.<br />
CONSTRUCTION<br />
1-Inner Conductor<br />
2-Insulation<br />
3-Communication Core<br />
4-Lay-Up<br />
5-Overall Screening<br />
6-Outer sheath<br />
Y<br />
2Y<br />
2X<br />
(St)<br />
Y<br />
• Electrolytic stranded annealed copper wire (IEC 60228, Class 2)<br />
• PVC ( EN 50290-2-21)<br />
PE (EN 50290-2-23)<br />
XLPE (EN 50290-2-29)<br />
• 0,50 mm² (7x0,30 mm) tinned or annealed standed copper, PE or XLPE insulated orange core.<br />
(More than one double or triple cables)<br />
• Screened pair cores are strand communication core with together twisted layers. Fixed with PES tape.<br />
• %100 Coverage AL-PES tape and 0,50 mm² (7x0,30 mm) tinned strand drain wire with screened..<br />
• PVC Sheath (EN 50290-2-22), RAL 9005 Black, RAL 5015 Blue or RAL 7001 Grey<br />
GENERAL FEATURES<br />
Flame Retardent<br />
(For a single cable)<br />
> IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2<br />
Oil Resistance<br />
> ICEA S-82-552<br />
Flame Retardent<br />
(For a Bunch Cable )<br />
> IEC 60332-3-24, EN 60332-3-24, VDE 0482-332-3-24<br />
UV Resistance<br />
> Only valid for Black sheath cables.<br />
Determination of Flame Particles<br />
Test (Test of determination of<br />
flaming droplets)<br />
> IEC 60332-1-3, EN 60332-1-3, VDE 0482-332-1-3<br />
TECHNICAL PROPERTIESTIES PVC (Y) PE (2Y) XLPE (2X)<br />
Fixed Flexible Fixed Flexible Fixed<br />
Flexible<br />
Temperature Range (°C) -30 °C …. +70 °C -5 °C …. +50 °C -30 °C …. +70 °C -5 °C …. +50 °C -30 °C …. +90 °C -5 °C …. +50 °C<br />
Min. Bending Radius (mm)<br />
7,5xD<br />
ELECTRICAL CHARACTERISTICS<br />
300 V 500 V<br />
Cross Section (mm²)<br />
0,5 0,75 1,0 1,3 1,5 2,5 0,5 0,75 1,0 1,3 1,5<br />
Conductor DC Resistance (Ω/km)<br />
36,8 25,0 18,5 14,2 12,3 7,56 36,8 25,0 18,5 14,2 12,3<br />
Insulation Resistance (M.Ω.km) PVC: ≥ 10 PE ve XLPE : ≥ 5000<br />
PVC: ≥ 10 PE ve XLPE : ≥ 5000<br />
Capacity (800 MHz) (pF/m)<br />
PVC: < 250 PE ve XLPE : < 150<br />
PVC: < 250 PE ve XLPE : < 150<br />
Capacity Unbalance<br />
PE for materials : 500 pF/ 500 m<br />
PE for materials : 500 pF/ 500 m<br />
L/R Raito (max.) (μH/Ω)<br />
25 25 25 40 40 60 25 25 25 40 40<br />
Operating Voltage<br />
Max. 300 V<br />
Max. 500 V<br />
Test Voltage (V ac) 1 minutes<br />
1000<br />
2000<br />
2,5<br />
7,56<br />
60<br />
PVC SHEATHED<br />
<strong>INSTRUMENTATION</strong> CABLES<br />
6.05<br />
ALTERNATIVE CABLE STRUCTURES<br />
Insulation<br />
Screen Features<br />
Sheath Features<br />
Yw – Heat-resistant PVC (105 °C), H – Halogen Free,<br />
C – Braid screen, (St)C – AL foil+Braid screen, CuB – Copper tape screened<br />
Yw – Heat-resistant PVC (105 °C), Yv – Reinforced sheath, 2Y – Polyethylene sheath<br />
CORE COLOURS 300 V 500 V<br />
www.klaskablo.com