RE-2Y(St)HSWAH-fl PIMF / TIMF<br />
RE-2X(St)HSWAH-fl PIMF / TIMF<br />
EN 50288-7<br />
Multi-Pair, Individual and Overall Screened, Round Steel Wire Armoured, Instrumentation Cables<br />
300 V-500 V<br />
KLAS KABLO RE-2Y(St)HSWAH-fl PIMF / TIMF<br />
APPLICATION<br />
These cables are generally employed in instrumentation and control systems, analog and digital signal transmission of chemical and petrochemical industrial<br />
premises, power plants, natural gas and petroleum industries, etc. Direct connection is not permitted under ambient with a low impedance sources. Cables with blue<br />
sheaths are suitable for security system applications. Furthermore, these cables can directly be buried in the soil. They are suitable in dry and wet indoor and outdoor<br />
installations.<br />
YAPI<br />
1-Inner conductor<br />
2-Insulation<br />
3-Individual Screen<br />
4-Communication Core<br />
5-Lay-Up<br />
6-Overall Screen<br />
7-Inner Sheath<br />
8-Armouring<br />
9-Outer Sheath<br />
2Y<br />
2X<br />
PIMF<br />
TIMF<br />
(St)<br />
H<br />
SWA<br />
H<br />
• Electrolytic stranded annealed copper wire (IEC 60228, Class 2)<br />
• PE (EN 50290-2-23)<br />
XLPE (EN 50290-2-29)<br />
• Dual cores are fixed with PES tape 0,60 mmØ with screened mono tinned drain wire and AL-PES tape.<br />
Triple cores are fixed with PES tape, 0,60 mmØ mono tinned drain wire and AL-PES tape with screened..<br />
• 0,50 mm² (7x0,30 mm) Tinned or annealed stranded copper, PE or XLPE insulated orange core.<br />
(Multi pair or triple cables)<br />
• Screened pair cores are strand communication core with together twisted layers. Fixed with PES tape.<br />
• %100 coverage AL-PES tape and 0,50 mm² (7x0,30 mm) screened with tinned strand drain wire.<br />
• HFFR sheath (EN 50290-2-27)<br />
• Round galvanized steel wire armour<br />
• HFFR Sheath (EN 50290-2-27), RAL 9005 Black, RAL 5015 Blue or RAL 7001 Grey<br />
GENERAL FEATURES<br />
Flame Retardent<br />
(For a single cable)<br />
TECHNICAL PROPERTIES PE (2Y) XLPE (2X)<br />
Fixed<br />
Flexible<br />
Fixed<br />
Flexible<br />
Temperature Range (°C) -30 °C …. +70 °C -5 °C …. +50 °C -30 °C …. +90 °C<br />
-5 °C …. +50 °C<br />
Min. Bending Radius (mm)<br />
10xD<br />
ELECTRICAL CHARACTERISTICS<br />
300 V 500 V<br />
Cross Section (mm²)<br />
0,5 0,75 1,0 1,3 1,5 2,5 0,5 0,75 1,0 1,3 1,5 2,5<br />
Conductor DC Resistance (Ω/km)<br />
36,8 25,0 18,5 14,2 12,3 7,56 36,8 25,0 18,5 14,2 12,3 7,56<br />
Insulation Resistance (M.Ω.km) PE ve XLPE : ≥ 5000<br />
PE ve XLPE : ≥ 5000<br />
Capacity (800 MHz) (pF/m)<br />
PE ve XLPE : < 150<br />
PE ve XLPE : < 150<br />
Capacity Unbalance<br />
PE for Materials : 500 pF/ 500 m<br />
PE for Materials : 500 pF/ 500 m<br />
L/R Raito (max.) (μH/Ω)<br />
25 25 25 40 40 60 25 25 25 40 40 60<br />
Operating Voltage<br />
Max. 300 V<br />
Max. 500 V<br />
Test Voltage (V ac) 1 minutes<br />
1000<br />
2000<br />
ALTERNATIVE CABLE CONSTRUCTIONS<br />
Insulation<br />
H – Halogen Free<br />
Individual Screen<br />
Screen Features<br />
Armour Features<br />
> IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2<br />
Flame Retardent (For > IEC 60332-3-24, EN 60332-3-24, VDE 0482-332-3-24<br />
a Bunch Cable )<br />
Determination of Flame > IEC 60332-1-3, EN 60332-1-3, VDE 0482-332-1-3<br />
Particles Test (Test of determination<br />
of flaming droplets)<br />
Halogen Acid > IEC 60754-1, EN 50267-2-1, VDE 0482-267-2-1<br />
Gas Test<br />
QIMF – Quad stranded screen<br />
Acidic (Corrosive)<br />
Gas Test<br />
Oil Resistance<br />
UV Resistance<br />
> ICEA S-82-552<br />
C – Braid screen, (St)C – AL foil+Braid screen, CuB – Copper tape screened<br />
B – Double layer steel or brass tapes, Q – Galvanized coated steel wire braid<br />
> Only valid for Black sheath cables..<br />
CORE COLOURS 300 V 500 V<br />
> IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2<br />
Smoke Density Test > IEC 61034-2, EN 61034-2, VDE 0482-1034-2<br />
HFFR SHEATHED<br />