RE-Y(St)YSWAY(ö)-fl PIMF / TIMF<br />

RE-2Y(St)YSWAY(ö)-fl PIMF / TIMF<br />

RE-2X(St)YSWAY(ö)-fl PIMF / TIMF<br />

EN 50288-7<br />

Multi-Pair, Individual and Overall Screened, Round Steel Wire Armoured, Oil Resistant Instrumentation Cables<br />

300 V - 500 V<br />

KLAS KABLO RE-Y(St)YSWAY(ö)-fl PIMF / TIMF<br />

APPLICATION<br />

These cables are generally employed in instrumentation and control systems, analog and digital signal transmission of chemical and petrochemical industrial premises,<br />

power plants, natural gas and petroleum industries, etc. Direct connection is not permitted under ambient with a low impedance sources. Cables with blue sheaths are<br />

suitable for security system applications. The cable armour protects the cable against mechanical impacts. Furthermore, these cables can directly be buried in the soil.<br />

They are suitable in dry and wet indoor and outdoor installations.<br />

CONSTRUCTION<br />

1-Inner Conductor<br />

2-Insulation<br />

3-Individual Screening<br />

4-Communication Core<br />

5-Lay-Up<br />

6-Overall Screening<br />

7-Inner Sheath<br />

8-Armouring<br />

9-Outer sheath<br />

• Electrolytic stranded annealed copper wire (IEC 60228, Class 2)<br />

Y<br />

• PVC (EN 50290-2-21)<br />

2Y<br />

PE (EN 50290-2-23)<br />

2X<br />

XLPE (EN 50290-2-29)<br />

• Double cores are fixed with PES tape, 0,60 mmØ mono tinned drain wire and AL-PES tape with screened.<br />

Triple cores are fixed with PES tape, 0,60 mmØ mono tinned drain wire and AL-PES tape with screened.<br />

.• 0,50 mm² (7x0,30 mm) tinned or annealed standed copper, PE or XLPE insulated orange core.<br />

(More than one double or triple cables)<br />

• Screened pair cores are strand communication core with together twisted layers. Fixed with PES tape.<br />

PIMF<br />

TIMF<br />

(St)<br />

• %100 Coverage AL-PES tape and 0,50 mm² (7x0,30 mm) tinned strand drain wire with screened..<br />

Y<br />

• PVC sheath (EN 50290-2-22)<br />

SWA<br />

• Round galvanized steel wire armours<br />

Y(ö)<br />

• PVC sheath (Aliphatic Hydrocarbon Resistant ), RAL 9005 Black, RAL 5015 Blue veya RAL 7001 Grey<br />

GENERAL FEATURES<br />

Flame Retardent<br />

(For a single cable)<br />

> IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2<br />

Mineral Oil Resistance > HD 505.2.1<br />

Flame Retardent<br />

(For a Bunch Cable)<br />

> IEC 60332-3-24, EN 60332-3-24, VDE 0482-332-3-24<br />

Determination of Flame Particles > IEC 60332-1-3, EN 60332-1-3, VDE 0482-332-1-3<br />

Test (Test of determination of<br />

flaming droplets)<br />

Oil Resistance<br />

> ICEA S-82-552<br />

ALTERNATIVE CABLE STRUCTURES<br />

Insulation<br />

Individual Screening<br />

Screen Features<br />

Armour Specifications<br />

Yw – Heat-resistant PVC (105 °C),<br />

QIMF – Quad stranded screened<br />

Aliphatic Hydrocarbon<br />

Resistance<br />

UV Resistance<br />

C – Braid screen, (St)C – AL foil+Braid screen, CuB – Copper tape screened<br />

B – Double layer steel or brass tapes, Q – Galvanized coated steel wire braid<br />

> NF M 87-202<br />

CORE COLOURS 300 V 500 V<br />

> Only valid for Black sheath cables.<br />

TECHNICAL PROPERTIESTIES<br />

PVC (Y) PE (2Y) XLPE (2X)<br />

Fixed Flexible Fixed Flexible Fixed<br />

Flexible<br />

Temperature Range (°C) -30 °C …. +70 °C -5 °C …. +50 °C -30 °C …. +70 °C -5 °C …. +50 °C -30 °C …. +90 °C -5 °C …. +50 °C<br />

Min. Bending Radius (mm)<br />

10xD<br />

ELECTRICAL CHARACTERISTICS<br />

300 V 500 V<br />

Cross Section (mm²)<br />

0,5 0,75 1,0 1,3 1,5 2,5 0,5 0,75 1,0 1,3 1,5 2,5<br />

Conductor DC Resistance (Ω/km)<br />

36,8 25,0 18,5 14,2 12,3 7,56 36,8 25,0 18,5 14,2 12,3 7,56<br />

Insulation Resistance (M.Ω.km) PVC: ≥ 10 PE ve XLPE : ≥ 5000<br />

PVC: ≥ 10 PE ve XLPE : ≥ 5000<br />

Capacity (800 MHz) (pF/m)<br />

PVC: < 250 PE ve XLPE : < 150<br />

PVC: < 250 PE ve XLPE : < 150<br />

Capacity Unbalance<br />

PE for materials : 500 pF/ 500 m<br />

PE for materials : 500 pF/ 500 m<br />

L/R Raito (max.) (μH/Ω)<br />

25 25 25 40 40 60 25 25 25 40 40 60<br />

Operating Voltage<br />

Max. 300 V<br />

Max. 500 V<br />

Test Voltage (V ac) 1 minutes<br />

1000<br />

2000<br />

OIL RESISTANCE PVC SHEATHED<br />

<strong>INSTRUMENTATION</strong> CABLES<br />

6.35<br />

www.klaskablo.com