06.09.2015 Views

INSTRUMENTATION

Untitled - Klas Kablo

Untitled - Klas Kablo

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

RE-2Y(St)CH-fl<br />

RE-2X(St)CH-fl<br />

EN 50288-7<br />

Multi-Pair, Braid+Metallic Screened, Instrumentation Cables300 V-500 V<br />

KLAS KABLO RE-2Y(St)CH-fl<br />

APPLICATION<br />

These cables are generally employed in instrumentation and control systems, analog and digital signal transmission of chemical and petrochemical industrial premises, power<br />

plants, natural gas and petroleum industries, etc. Direct connection is not permitted under ambient with a low impedance sources. Cables with blue sheaths are suitable for<br />

security system applications. Furthermore, these cables can directly be buried in the soil. They are suitable in dry and wet indoor and outdoor installations.<br />

CONSTRUCTION<br />

GENERAL FEATURES<br />

1-Inner Conductor<br />

2-Insulation<br />

3-Communication<br />

Core<br />

4-Lay-Up<br />

5-Overall Screening<br />

6-Outer sheath<br />

• Electrolytic stranded annealed copper wire (IEC 60228, Class 2)<br />

2Y • PE (EN 50290-2-23)<br />

2X XLPE (EN 50290-2-29)<br />

• 0,50 mm² (7x0,30 mm) tinned or annealed standed copper, PE or XLPE insulated orange core.<br />

(More than one double or triple cables)<br />

• Screened pair cores are strand communication core with together twisted layers. Fixed with PES tape.<br />

(St)C • %100 Coverage AL-PES tape and tinned copper wire braid with screened.<br />

H • HFFR sheath (EN 50290-2-27), RAL 9005 Black, RAL 5015 Blue or RAL 7001 Grey<br />

Flame Retardent<br />

(For a single cable)<br />

Flame Retardent<br />

(For a Bunch Cable)<br />

Determination of Flame Particles<br />

Test (Test of determination of<br />

flaming droplets)<br />

Halogen Acid Gas Test<br />

> IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2<br />

> IEC 60332-3-24, EN 60332-3-24, VDE 0482-332-3-24<br />

> IEC 60332-1-3, EN 60332-1-3, VDE 0482-332-1-3<br />

> IEC 60754-1, EN 50267-2-1, VDE 0482-267-2-1<br />

Asidic (Corrosive)<br />

Gas Test<br />

Smoke Density Test > IEC 61034-2, EN 61034-2,<br />

VDE 0482-1034-2<br />

Oil Resistance > ICEA S-82-552<br />

UV Resistance<br />

> IEC 60754-2, EN 50267-2-2,<br />

VDE 0482-267-2-2<br />

> Only valid for Black sheath cables.<br />

TECHNICAL PROPERTIESTIES<br />

PE (2Y)<br />

XLPE (2X)<br />

Fixed<br />

Flexible<br />

Fixed<br />

Flexible<br />

Temperature Range (°C) -30 °C …. +70 °C<br />

-5 °C …. +50 °C<br />

-30 °C …. +90 °C<br />

-5 °C …. +50 °C<br />

Min. Bending Radius (mm)<br />

7,5xD<br />

ELECTRICAL CHARACTERISTICS<br />

300 V 500 V<br />

Cross Section (mm²)<br />

0,5 0,75 1,0 1,3 1,5 2,5 0,5 0,75 1,0 1,3 1,5 2,5<br />

Conductor DC Resistance (Ω/km)<br />

36,8 25,0 18,5 14,2 12,3 7,56 36,8 25,0 18,5 14,2 12,3 7,56<br />

Insulation Resistance (M.Ω.km) PE ve XLPE : ≥ 5000<br />

PE ve XLPE : ≥ 5000<br />

Capacity (800 MHz) (pF/m)<br />

Capacity Unbalance<br />

PE ve XLPE : < 150<br />

PE for materials : 500 pF/ 500 m<br />

PE ve XLPE : < 150<br />

PE for materials : 500 pF/ 500 m<br />

L/R Raito (max.) (μH/Ω)<br />

25 25 25 40 40 60 25 25 25 40 40 60<br />

Operating Voltage<br />

Max. 300 V<br />

Max. 500 V<br />

Test Voltage (V ac) 1 minutes<br />

1000<br />

2000<br />

HFFR SHEATHED CABLES<br />

6.47<br />

ALTERNATIVE CABLE STRUCTURES<br />

Insulation<br />

Screen Features<br />

H – Halogen Free<br />

C – Braid screen, CuB – Copper tape screened<br />

CORE COLOURS 300 V 500 V<br />

www.klaskablo.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!