PRECISEPOWER SPECIFICATIONS:<br />

CONTROLLERS<br />

General<br />

Specifications PRECISEPOWER 300<br />

(PS1D-EA-00300)<br />

Range & Features<br />

PRECISEPOWER 2000<br />

(PS10-EA-02000)<br />

Input voltage 90-264VAC Single phase 90-240VAC single phase or three phase<br />

Input frequency 50-60 Hz 50-60 Hz<br />

Input inrush<br />

current<br />

Input current at<br />

240VAC single<br />

phase & 2000 DC<br />

watts output<br />

Output power<br />

Output voltage<br />

6.8 A at 240 VAC in 6.7A at 240VAC input<br />

-- 12.4A RMS, 30A peak<br />

300 watts RMS @ 120VAC<br />

600 watts RMS @ 240VAC<br />

DC no load = (1.41 X VAC RMS input)– 2 Volts<br />

DC full load @ 300W = (DC no load) X 0.96<br />

DC full load @ 600W = (DC no load) X 0.93<br />

Nominal range of 167 VDC to 337 VDC<br />

% Regulation -- 5 to 7%<br />

Cat 3<br />

No, single relay standard<br />

MAXIMUM<br />

1000 Watts free air @ 240VAC single phase input<br />

2000 Watts forced air @ 240VAC single phase input<br />

2100 Watts forced air @ 208VAC 3 phase input<br />

3400 Watts forced air @ 240VAC 3 phase input<br />

DC no load = (1.41 X VAC RMS phase-to-phase input) - 2 Volts<br />

DC full load single phase = (DC no load) X 0.93<br />

DC full load three phase = (DC no load) X 0.97<br />

Yes, when used with Precise Automation software and I2C<br />

communication, dual relay standard<br />

Fault detection -- Output short circuit, output overload, missing third AC phase<br />

Dimensions 135 mm x 76 mm x 60 mm 270 mm x 105 mm x 76 mm<br />