Commissioning<br />
5 Commissioning and operation<br />
Warning!<br />
Do not touch live connections and/or the moving rotor.<br />
The motor must be turned off whilst brake function is being tested.<br />
5.1 Function test<br />
Refer to chapter 7 Troubleshooting and fault elimination.<br />
5.1.1 Release / voltage check<br />
Applies only to brakes without microswitches.<br />
Warning!<br />
The brake must be torque-free and the motor not running.<br />
Warnung!<br />
Do not touch live connections.<br />
1. Remove two bridges from the motor terminals. Do not turn off brake DC power supply. The<br />
neutral conductor must also be connected to the motor neutral point when the rectifier is<br />
connected to that point.<br />
2. Turn on the current.<br />
3. Measure the DC brake voltage.<br />
4. Compare the result with the nameplate voltage rating. Deviations of up to 10% are<br />
acceptable.<br />
5. Check the air gap s Lü . It must be zero and the rotor freely rotatable.<br />
6. Turn the power supply off.<br />
7. Screw bridges to the motor terminals. Remove the additional neutral conductor.<br />
5.1.2 Microswitch - wear check<br />
Warning!<br />
The brake must be torque-free and the motor not running.<br />
Warnung!<br />
Do not touch live connections.<br />
BA <strong>BFK</strong>454 GB 3.0<br />
25