Troubleshooting and fault elimination<br />
Fault Cause Remedy<br />
AC and mains voltage do not tally Missing or defective fusing Choose a terminal post that has fusing and is OK.<br />
Microswitch incorrectly wired<br />
Microswitch defective or incorrectly set<br />
Check and correct microswitch wiring.<br />
Replace entire stator and return defective unit to the<br />
maker.<br />
Signal S g a ”wear limit reached” ed at Microswitch incorrectly wired Check and correct microswitch wiring.<br />
s Lü s Lü max. Microswitch incorrectly set. Replace the entire stator and return the defective unit<br />
to the maker.<br />
Signal S g a ”wear limit reached ed ” not<br />
Microswitch incorrectly wired<br />
Check and correct microswitch wiring.<br />
transmitted at s Lü s Lü max. Microswitch incorrectly set or defective Replace the entire stator and return the defective unit<br />
to the maker.<br />
<strong>Power</strong> supply cable broken<br />
Replace defective cable<br />
<strong>Brake</strong> distance too great switching time too long Turn the DC power off (see wiring diagram).<br />
Friction surface dirty<br />
Replace brake. Return defective unit to maker for<br />
repair.<br />
<strong>Brake</strong> torque too low<br />
Adjust brake torque.<br />
<strong>Brake</strong> distance too short <strong>Brake</strong> torque too high Adjust brake torque, check twin-circuit function<br />
(chapter 5.1.3)<br />
BA <strong>BFK</strong>454 GB 3.0<br />
37