32 SEBU8180-01<br />

<strong>Operation</strong> Section<br />

Features <strong>and</strong> Controls<br />

Theenginecanbe programmed to the following<br />

modes:<br />

“Warning”<br />

Sensors <strong>and</strong> Electrical<br />

Components<br />

i02861773<br />

The “Warning” lamp <strong>and</strong> the warning signal (orange<br />

lamp) turn “ON” <strong>and</strong> the warning signal is activated<br />

continuously in order to alert the operator that one or<br />

more of the engine parameters is not within normal<br />

operating range.<br />

“Warning/Derate”<br />

The “Diagnostic” lamp turns “ON” <strong>and</strong> the warning<br />

signal (red lamp) is activated. After the warning, the<br />

engine power will be derated. The warning lamp will<br />

begin to flash when the derating occurs.<br />

SMCS Code: 1900; 7400<br />

Sensor Locations<br />

Illustration 26 shows the typical locations of the<br />

sensors <strong>and</strong> the ECM on the engine. Specific engines<br />

may appear different from the illustration due to<br />

differences in applications.<br />

The engine will be derated if the engine exceeds<br />

preset operational limits. The engine derate is<br />

achieved by restricting the amount of fuel that is<br />

available for each injection. The amount of this<br />

reduction of fuel is dependent on the severity of the<br />

fault that has caused the engine derate, typically up<br />

to a limit of 50%. This reduction in fuel results in a<br />

predetermined reduction in engine power.<br />

“Warning/Derate/Shutdown”<br />

The “Diagnostic” lamp turns “ON” <strong>and</strong> the warning<br />

signal (red lamp) is activated. After the warning,<br />

the engine power will be derated. The engine will<br />

continue at the rpm of the set derate until a shutdown<br />

of the engine occurs. The engine can be restarted<br />

after a shutdown for use in an emergency.<br />

Ashutdown of the engine may occur in as little<br />

as 20 seconds. The engine can be restarted after<br />

ashutdownforuseinanemergency.However,<br />

the cause of the initial shutdown may still exist.<br />

The engine may shut down again in as little as 20<br />

seconds.<br />

If there is a signal for low oil pressure or for coolant<br />

temperature, there will be a two second delay in<br />

order to verify the condition.<br />

For each of the programmed modes, refer to<br />

Troubleshooting Guide, “Indicator Lamps” for more<br />

information on Indicator Lamps.<br />

For more information or assistance for repairs,<br />

consult your Caterpillar dealer.