Special 2-step mode for robot interface<br />
N.B.! The parameters for the “Special 2-step mode for robot<br />
interface” are available when a robot interface or a field-bus<br />
coupler for robot control is connected up to the LocalNet.<br />
I-S ... Starting ... 0 - 200 % of the welding current<br />
Factory setting: 135 %<br />
SL ... Slope ... 0.1 - 9.9 s, Factory setting: 1.0 s<br />
I-E ... End current ... 0 - 200 % of the welding current<br />
Factory setting: 50 %<br />
t-S ... Duration of starting current ... OFF / 0.1 ... 9.9 s<br />
Factory setting: OFF<br />
t-E ... Duration of end current ... OFF / 0.1 ... 9.9 s<br />
Factory setting: OFF<br />
N.B.! The above parameters are illustrated by a graph in the<br />
section headed “MIG/MAG welding”.<br />
Parameters for "Aluminium 4-step" mode<br />
I-S ...<br />
Starting current ... 0 - 200 % of welding current<br />
Factory setting: 135 %<br />
SL ... Slope ... 0.1 - 9.9 s, Factory setting: 1 s.<br />
I-E ... End current ... 0 - 200 % of welding current<br />
Factory setting: 50 %<br />
Parameters for "Spot welding" mode<br />
SPt ... Spot-welding time ... 0,1 - 5,0s, Factory setting: 1.0s<br />
2nd - Second level of Set-up Menu<br />
The following functions are located in a second menu level:<br />
- PPU (push-pull unit)<br />
- C-C (cooling unit cut-out)<br />
- Ito (ignition time-out)<br />
Changing to the second menu level (2nd)<br />
- Choose the parameter “2nd”, as described in the sections<br />
headed "Acessing the setup-menu"<br />
- Press and hold the MEM button<br />
- Press the Process button<br />
- Release the MEM button<br />
The power source is now in the second menu level (2nd) of the<br />
set-up menu. The function “PPU” (Push-Pull Unit) is now<br />
displayed.<br />
Select function<br />
- Select the required function with the Process button<br />
- Set up the function as described in the following sections<br />
Exit from the second menu level (2nd)<br />
- Press the MEM button<br />
N.B! Any changes only become active if you switch to a different<br />
function or exit from the second menu level (2nd).<br />
PPU... Push-Pull Unit (see the section headed “Push-Pull<br />
Unit”)<br />
C-C ... Cooling unit cut-out ... ON / OFF / Aut<br />
Factory setting: Aut (automatic)<br />
Ito ...<br />
Ignition Time-Out ... OFF / 5 ... 100 mm length of wire is<br />
fed until the safety cut-out is triggered, factory setting:<br />
OFF<br />