08.12.2012 Views

technical & service manual split system air conditioner

technical & service manual split system air conditioner

technical & service manual split system air conditioner

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

4. REFRIGERANT FLOW DIAGRAM<br />

Indoor Unit AWR222CLE Outdoor Unit AER222SC<br />

AER222SC3<br />

Indoor Unit Outdoor Unit<br />

Muffler<br />

Evaporator<br />

Wide tube<br />

O.D.<br />

ø15.88 mm<br />

(5/8 ")<br />

Narrow tube<br />

O.D.<br />

ø6.35 mm<br />

(1/4")<br />

Insulation of Refrigerant Tubing<br />

IMPORTANT<br />

Wide tube<br />

<strong>service</strong><br />

valve<br />

Narrow<br />

tube<br />

<strong>service</strong><br />

valve<br />

Check port<br />

Capillary tube<br />

10<br />

Muffler<br />

Because capillary tubing is used in the outdoor unit, both the<br />

wide and narrow tubes of this <strong>air</strong> <strong>conditioner</strong> become cold. To<br />

prevent heat loss and wet floors due to dripping of<br />

condensation, both tubes must be well insulated with a proper<br />

insulation material. The thickness of the insulation should be a<br />

min. 8 mm.<br />

CAUTION<br />

After a tube has been insulated,<br />

never try to bend it into a narrow<br />

curve because it can cause the tube<br />

to break or crack.<br />

Accumulator<br />

Capillary for<br />

liquid injection<br />

Thickness:<br />

Min. 8 mm<br />

Wide tube<br />

Drier<br />

Condenser<br />

Compressor<br />

Insulation<br />

Narrow tube<br />

Thickness:<br />

Min. 8 mm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!