D. Check transformer in indoor unit.<br />

• Measure resistance of primary and<br />

secondary winding.<br />

(TR1)<br />

E. Check fuse on the indoor PCB Ass'y.<br />

• Check fuse on indoor PCB Ass'y<br />

for continuity. (F)<br />

OK<br />

• Check operation lamp to see<br />

if light is ON.<br />

Light is OFF<br />

• Measure resistance of primary and<br />

secondary winding of transformer.<br />

(TR)<br />

OK<br />

• Indoor PCB Ass'y or switch Ass'y<br />

is defective.<br />

F. Check TIMER SELECT button on the remote control unit.<br />

• Timer is turned ON. Check to see<br />

if ON or is displayed on<br />

remote control<br />

If fuse has been blown,<br />

YES<br />

27<br />

• Measure resistance of indoor<br />

fan motor winding.<br />

(FMI)<br />

OK<br />

• Measure resistance of louver<br />

motor winding. (LM)<br />

OK<br />

• Measure coil resistance of magnetic<br />

contactor<br />

(MG)<br />

OK<br />

• Check crank case heater<br />

• Replace the fuse.<br />

OK<br />

Cancel the timer mode.<br />

(CH)