6. ELECTRICAL DATA<br />

6-1. Electrical Characteristics<br />

Indoor Unit AWR222CLE<br />

Outdoor Unit AER222SC<br />

Indoor Unit AWR222CLE<br />

Outdoor Unit AER222SC3<br />

Indoor Unit Outdoor Unit Complete Unit<br />

Fan Motor Fan Motor Compressor<br />

Performance at 220V Single phase 50Hz 380V Three phase 50Hz<br />

Rating Conditions Running Amps. A 0.35 0.54 4.21 4.5<br />

Power Input kW 0.077 0.116 2.557 2.75<br />

Full Load Conditions Running Amps. A 0.35 0.54 5.31 5.6<br />

Power Input kW 0.077 0.116 3.237 3.43<br />

Rating Conditions : Indoor Air Temperature 27°C D.B. / 19°C W.B.<br />

Outdoor Air Temperature 35°C D.B.<br />

Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.<br />

Outdoor Air Temperature 43°C D.B.<br />

Indoor Unit Outdoor Unit Complete Unit<br />

Fan Motor Fan Motor Compressor<br />

Performance at 220 / 240V Single phase 50Hz<br />

Rating Conditions Running Amps. A 0.35 / 0.37 0.54 / 0.55 12.21 / 12.08 13.1 / 13.0<br />

Power Input kW 0.077 / 0.089 0.116 / 0.134 2.657 / 2.727 2.85 / 2.95<br />

Full Load Conditions Running Amps. A 0.35 / 0.37 0.54 / 0.55 15.21 / 15.18 16.1 / 16.1<br />

Power Input kW 0.077 / 0.089 0.116 / 0.134 3.307 / 3.307 3.50 / 3.53<br />

Rating Conditions : Indoor Air Temperature 27°C D.B. / 19°C W.B.<br />

Outdoor Air Temperature 35°C D.B.<br />

Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.<br />

Outdoor Air Temperature 43°C D.B.<br />

16