01.04.2017 Views

The_models__dimensions_2017_

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Cut-out <strong>dimensions</strong> for appliance combinations in the 400 series. Calculator for calculating the width<br />

of the cut-out.<br />

Calculation of the width of the cut-out for a surface mounting<br />

Example using a combination of VI 414, VI 424, VP 414 and 2 VL 414.<br />

Example<br />

Your combination<br />

Total width of all appliances in mm (3x 380) + (2x 110) 1.360 ……………………………………………<br />

+ Number of connection strips x 3 mm 4 x 3 + 12 ……………………………………………<br />

– Lateral appliance projection (10 mm / side) 20 – 20 – 20<br />

(A) Total width of the cut-out (in mm) 1.352 +/– 2 ………………………………… +/– 2<br />

Cut-out depth based on the installation situation with or without appliance cover/filler strip.<br />

Calculation of the width of the cut-out for a flush mounting<br />

Example using a combination of VI 414, VI 424, VP 414 and 2 VL 414.<br />

Example<br />

Your combination<br />

Total width of all appliances in mm (3x 380) + (2x 110) 1.360 ……………………………………………<br />

+ Number of connection strips x 3 mm 4 x 3 + 12 ……………………………………………<br />

– Lateral appliance projection (10 mm / side) 20 – 20 – 20<br />

(A) Total width of the cut-out (in mm) 1.352 +/– 2 ………………………………… +/– 2<br />

+ Lateral appliance projection (10 mm / side) 20 + 20 + 20<br />

+ Silicone joint (3 mm circumference) 2 x 3 + 6 + 6<br />

(B) Total width with groove (in mm) 1.378 + 2 ………………………………… 0/+ 2<br />

Cut-out depth based on the installation situation with or without appliance cover/filler strip.