Ventilation appliances<br />

241<br />

Air extraction<br />

– Installation with the flat duct connecting piece CA 284 010 (available as a special accessory).<br />

– Maximum length of the air extraction ducting system 6 m to assure good performance.<br />

– For optimum air circulation, we recommend ducts with DN 150. Ducting and connection pieces are available as special accessories.<br />

– Two flat ducts must be connected with a pipe connector.<br />

– It is also important that ducting is well sealed in order to prevent air leaks, e.g. by using the adhesive tape AD 990 090 (UV- and heat-resistant).<br />

Planning example 3<br />

CV 282 with air extraction connecting piece CA 284 010<br />

Wall installation, worktop depth 60 cm,<br />

connection to a wall outlet with telescopic duct.<br />

Planning example 4<br />

CV 282 with air extraction connecting piece CA 284 010<br />

Island installation, worktop depth 1.20 m,<br />

ducting directed to the outside via the cellar.<br />

Planning example 5<br />

CV 282 with air extraction connecting piece CA 284 010<br />

Wall installation, worktop depth 70 cm,<br />

ducting behind the cabinet and in the plinth.