Wall Units, Type SW, W, AW<br />

Floor Standing Units,<br />

Type SFK, SFG, FK, FG, AK, AG<br />

Recessed Unit, Type RK, RG, SK, SG<br />

A + 3” (76)<br />

A – See Note 1<br />

Dimensions in bold or ( ) are in millimeters.<br />

Dimensional<br />

<strong>Data</strong><br />

Cabinet Dimensions<br />

Airflow Arrangements<br />

Table DD-1 — Types SW, W, AW Wall Hung Units<br />

Length A (All Units)<br />

26 (660) 32 (813) 38 (965) 44 (1118) 50 (1270) 56 (1422) 62 (1575) 68 (1727)<br />

Depth B 4 3 /16” (106) Depth B 6 3 /16” (157) Depth B 8 3 /16” (208)<br />

C D C D C D<br />

10 (254) 2 (51) 12 (305) 3 (76)<br />

14 (356) 2 (51) 16 (406) 3 (76) 16 (406) 4 (102)<br />

18 (457) 2 (51) 20 (508) 3 (76) 20 (508) 4 (102)<br />

24 (610) 2 (51) 26 (660) 3 (76) 26 (660) 4 (102)<br />

30 (762) 2 (51) 32 (813) 3 (76) 32 (813) 4 (102)<br />

NOTE: 8 3 /16” (208) deep cabinet not available in type AW unit.<br />

Table DD-2 — Types SFK, SFG, FK, FG, AK, AG Floor Standing Units<br />

Length A (All Units)<br />

26 (660) 32 (813) 38 (965) 44 (1118) 50 (1270) 56 (1422) 62 (1575) 68 (1727)<br />

Depth B 4 3 /16” (106) Depth B 6 3 /16” (157) Depth B 8 3 /16” (208)<br />

C D E C D E C D E<br />

14 (356) 2 (51) 4 (102) 16 (406) 3 (76) 4 (102)<br />

18 (457) 2 (51) 4 (102) 20 (508) 3 (76) 4 (102) 20 (508) 4 (102) 4 (102)<br />

24 (610) 2 (51) 6 (152) 26 (660) 3 (76) 6 (152) 26 (660) 4 (102) 6 (152)<br />

30 (762) 2 (51) 6 (152) 32 (813) 3 (76) 6 (152) 32 (813) 4 (102) 6 (152)<br />

36 (914) 2 (51) 6 (152) 38 (965) 3 (76) 6 (152) 38 (965) 4 (102) 6 (152)<br />

NOTE: 8 3 /8” (213) deep cabinet not available in type AK and AG unit.<br />

Table DD-3 — Types RK, RG Fully-Recessed and Types SK, SG Semi-Recessed Units<br />

Length A (All Units)<br />

26 (660) 32 (813) 38 (965) 44 (1118) 50 (1270) 56 (1422) 62 (1575) 68 (1727)<br />

Depth B 4” (102) Depth B 6” (152) Depth B 8” (203)<br />

C D E F G C D E F G C D E F G<br />

14 (356) 2 (51) 4 (102) 16 (406) 3 (76) — — 7 /16 (11)<br />

18 (457) 2 (51) 7 /16 (11) 3 9 /16 (90) 5 (127) 20 (508) 3 (76) 7 /16 (11) 5 9 /16 (141) 20 (508) 4 (102) 2 1 /2 (64) 7 9 /16 (192)<br />

24 (610) 2 (51) or or 5 (127) 26 (660) 3 (76) or or 5 1 /8 (130) 26 (660) 4 (102) or 5 1 /2 (140) 5 1 /8 (130)<br />

30 (762) 2 (51) 1 1 /2 (38) 2 1 /2 (64) 5 (127) 32 (813) 3 (76) 2 1 /2 (64) 3 1 /2 (89) 32 (813) 4 (102) 4 1 /2* (114) or<br />

36 (914) 2 (51) 5 (127) 38 (965) 3 (76) 38* (965) 4 (102) 3 1 /2* (89)<br />

NOTE: Dimensions E and F — Top dimension for Types RK & RG fully-recessed units and bottom dimension(s) for Types SK & SG semi- recessed units.<br />

Type *SK-SG — semi-recessed convectors only 38” (965) high with 4 1 /2” (114) projection, 3 1 /2” (89) recess can not be furnished.<br />

24<br />

C+<br />

1 1/2 (38)<br />

C<br />

See Note 1<br />

NOTES:<br />

1. Add 1/4” (6) to a dimension for rough length opening. Add 1/8 (3) to C dimension for rough height opening.